background image

Step 4

Step 5

Step 6

4. Connect the lamp connector 

securely onto the AHPCO Cell.

6. Slide shell down onto base and 

replace screws.  (Cord and 

switch are to the back.)

5. Use a  5/16 inch socket to 

tighten nuts to secure the AHPCO 

Cell.

6

Summary of Contents for 203758

Page 1: ...s Warranty Safety Warnings Operating Instructions Replacement Directions Troubleshooting Tips Cleaning and Maintenance Tips Before operating this unit carefully read the contents of this manual Filterless UV Air Purifier Item No 203758 ...

Page 2: ...e operating your air purifier Table of Contents Table of Contents 1 Safety Instructions and Cautions 2 Warranty 3 Maintenance and Customer Service 4 Placement and Operation 4 Cleaning 4 AHPCO Cell Replacement 5 6 Troubleshooting Guide 7 1 ...

Page 3: ...followed WARNING To reduce the risk of fire electric shock or injury Do not use outdoors or on wet surfaces Use only as described in this manual Do not use with a damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water call Customer Service at 1 877 714 7444 Do not unplug by pulling on cord To unplug grasp the plug not the cord Do ...

Page 4: ...uct If you purchase this product from any other source your purchase is AS IS which means Sharper Image grants you no warranty and that you not Sharper Image assume the entire risk of the quality and performance of this product including the entire cost of any necessary servicing or repairs of any defects Sharper Image s liability for damages to you for any costs whatsoever arising out of this sta...

Page 5: ...uild up Aluminum Shell We recommend using stainless steel aluminum spray on polish or multi surface cleaners Make sure the polish or cleaner is recommended for use on aluminum Internal Take a dry cloth and wipe inside the shell and around the aluminum brackets and the ballast or spray with compressed air NOTE Use compressed air only to clean the AHPCO Cell Any removal of cata lyst coating will dec...

Page 6: ... AHPCO Cell and pull upward to release from bracket then remove the lamp connector 2 Use a 5 16 inch socket to remove the nuts from the AHPCO Cell CAUTION UV lamp may be hot and could cause serious burns if not handled properly Please wait until AHPCO Cell has cooled to room temperature to remove from unit 5 WARNING OPTICAL RADIATION EXPOSURE HAZARD DO NOT ATTEMPT TO OPERATE UNIT WITHOUT ALLUMINUM...

Page 7: ...5 Step 6 4 Connect the lamp connector securely onto the AHPCO Cell 6 Slide shell down onto base and replace screws Cord and switch are to the back 5 Use a 5 16 inch socket to tighten nuts to secure the AHPCO Cell 6 ...

Page 8: ...lugged 1 Check to make sure the AHPCO Cell s four pins are plugged in completely and the cell has a blue glow If you see no glow contact Sharper Image Customer Service Customer Service number 1 877 714 7444 TOLL FREE Monday Friday 9 00 a m to 6 00 p m EST Email customerservice sharperimageonline com Please include where the product was purchased from as well as the date that the product was purcha...

Reviews: