XL-MP110H/MP110E
2 – 4
[3] Standard Specification of Stereo System Error Message Display Contents
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**'. 'ER-CD**' display will only be display when error had
been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occurred, the unit will automatically enter to stand-by mode and Timer indicator will
flashing as below.
Example:In case of speaker abnormal
BEFORE TRANSPORTING THE UNIT
The following process need to be taken after set tapering/parts replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the
button and the X-BASS/DEMO button, press the ON/STAND-BY button. The Micro Computer version number will
be displayed as "AM******".
3. Press OPEN/CLOSE button until "WAIT"--> "FINISHED" appears.
4. Unplug the AC cord and the unit is ready for transporting.
Error Contents
DISPLAY
Notes
CD
Pickup Mechanism Error.
'ER-CD01'
PU-IN SW Detection NG.
CD Changer Mechanism Error. 'ER-CD**' (*)
10: CAM SW Detection NG during normal operation
11: CAM SW Detection NG during initialize process
20:TRAY SW Detection NG during normal operation
21:TRAY SW Detection NG during initialize process
CD DSP Communication Error. 'ER-CD31'
DSP COMMUNICATION ERROR.
Focus Not Match/IL Time Over. 'NO DISC'
TUNER
PLL Unlock.
FM
MHz
PLL Unlock.
87.50
TIMER
LED
OFF
OFF
OFF
OFF
1 FRAME
(REPEAT)
FLASHING
FLASHING
NO. 2
NO. 2
ON
ON
NO. 1 : +B PROTECTION
NO. 2 : Speaker abnormal
NO. 1
NO. 1
Summary of Contents for XL-MP110E
Page 26: ...XL MP110H MP110E 5 3 MEMO ...
Page 68: ...XL MP110H MP110E 8 11 MEMO ...
Page 97: ... MEMO XL MP110H MP110E ...
Page 98: ... MEMO XL MP110H MP110E ...
Page 99: ... MEMO XL MP110H MP110E ...