Once the "Multiple Control" mode has been identified we can now proceed to the "Projector
Setting " menu option under the "File" menu. (Refer to Figure 5)

Figure 5

From the "Projector Setting" Mode we identify the "ID" Number which will be used by the projector.
(Refer to Figure 6)

This "ID" number is selected and inputted on the Projector from the projector menu under "Options
2" (Refer to ID number Setup on page 4). This "ID" number is an additional option to help the enduser 
/ customer to better identify, monitor and control Sharp projectors which are attached to a Network.

Identify "Port" as LAN and Input the IP address. (Refer to Figure 6)

NOTE: IP address must be obtained from you IT / MIS Department

L:\tekcentr\CACTrain\SPS_ntwk

11

10/16/2001

Summary of Contents for XG-V10WLP

Page 1: ...M XG V10XM Sections 1 AN L10T Optional Card Installation 2 Projector Menu Configuration 3 S A P S Software Configuration Sharp Projector s Network Configuration Operation Manual For The L tekcentr CACTrain SPS_ntwk 1 10 16 2001 ...

Page 2: ...ctors are network accessible through the AN L10T optional 10Base T Network adapter This optional card enables the enduser to control and monitor projector operations through an existing LAN Network In order to configure the XG V10W XU M projectors to an existing LAN the following must occur 1 Install AN L10T Optional LAN Board 2 Configure XG V10W XU M Projector Menu Setup 2 Configure S A P S Softw...

Page 3: ...mber 2 Only needs to be done if expansion slot is used for first time 4 Remove the cover plate from the optional expansion board that will be installed into the slot 5 Insert the expansion board into the connector Refer to Figure C 6 Secure the expansion cover to the board Expansion Slot Closed with cover Screws that secure Expansion Plate cover Fig A FIG A Expansion Board Installation L tekcentr ...

Page 4: ...ure shield Fig B NOTE The RF Shield only needs to be removed if expansion slot is used for first time FIG C Expansion Card Connector Expansion Slot with RF shield Expansion Slot Open empty L tekcentr CACTrain SPS_ntwk 4 10 16 2001 ...

Page 5: ...eed to the Projector menu Options 2 and toggle down to the Set ID Number using the down arrow button on the projector The example we are using is ID 11 as indicated above 2 When the LAN board is installed select Menu Button OPTIONS 2 from the menu screen LAN BOARD will appear for the option board setting Projector Menu SetUp for the AN L10T Optional Expansion Board L tekcentr CACTrain SPS_ntwk 5 1...

Page 6: ...ption to be configured is IP Address Set When that option is selected the following menu will appear NOTE The fields following IP Address Set will be blank if the LAN Card is used for first time For Example Only NOTE The IP Address used is an example ONLY This information is obtained through the IT MIS Department L tekcentr CACTrain SPS_ntwk 6 10 16 2001 ...

Page 7: ...et will be blank if the LAN Card is used for first time For Example Only A Gateway is a network point that acts as an entrance to another network On the network a node or stopping point can be either a gateway node or a host end point node Both the computers of Internet users and the computers that serve pages to users are host nodes The computers that control traffic within your company s network...

Page 8: ...most networks subnets are defined as all devices whose IP addresses have the same prefix For example all devices with IP addresses that start with 100 100 100 would be part of the same subnet Dividing a network into subnets is useful for both security and performance reasons IP networks are divided using a subnet mask NOTE IP Address Gatway Set Subnet Mask addresses must be obtained from IT MIS De...

Page 9: ...Refer to Figure 1 Figure 1 If the projector is in Single projector mode you must change to Multiple projector mode Through this menu also select Use ID Number This can be accomplished through the File menu option Operation Mode Setting Refer to Figure 2 Figure 2 Identify the Multiple Projector Operation Mode setting and the Use ID Numbers option Once the Projector Operation Mode setting has been c...

Page 10: ...ptions menu to continue with the network configuration involving the SAPS software In Single Projector mode the Network control options menu items are inactive Refer to Figure 4 Single Projector Control is for RS232 connection Figure 3 Figure 4 L tekcentr CACTrain SPS_ntwk 10 10 16 2001 ...

Page 11: ...gure 6 This ID number is selected and inputted on the Projector from the projector menu under Options 2 Refer to ID number Setup on page 4 This ID number is an additional option to help the enduser customer to better identify monitor and control Sharp projectors which are attached to a Network Identify Port as LAN and Input the IP address Refer to Figure 6 NOTE IP address must be obtained from you...

Page 12: ... box After confirming adjusting the Projector Setting menu the Apply button will become active Not ghosted click the apply button and then the OK button and your projector s ID number and the port idendified will appear under the All Projector List Refer to Figure 7 Figure 7 L tekcentr CACTrain SPS_ntwk 12 10 16 2001 ...

Page 13: ...e is not specifically necessary for configuring the XG V10 projector to an existing network it does however offer another opportunity to further help with the process of identifying a projector within a LAN while also assisting the Network Projector Administrator with projector identification by adding a Projector Name Refer to Figure 9 NOTE The Unique Name field is optional and does not appear on...

Page 14: ...ing to help the Administrator identify the projector and or placement of the Unit For example the projector could have been called 3rdFl ConRm or Cafeteria depending on the physical layout and or number of projectors involved Refer to Figure 10 NOTE the Projector Name field is limited to 12 Characters Maximum NOTE the SAPS software can control up to 250 individual or grouped projectors Please refe...

Page 15: ...fer to Figure 12 NOTE Email address must be entire address even if individual is local Refer to Figure 12 3 One of the major advantages of using the SAPS software with the Networked V10 is status and diagnostics of the projector s The E mail function e mails your projector failure problems while also giving the E mail recipients an overall status report The Status report timing when E mail is sent...

Page 16: ...nistrators e mail address as defined by the Network Administrator your E mail address on the company Server The Sender Name is your name Figure 14 Sender Infromation allows you to add your general comments to any e mail sent out This concludes the S A P S section on Network Setup Assuming that all the information is correct and all the following steps were followed the last item is to Scan the net...

Page 17: ... Once the LAN address is entered depress the Add button and the IP address will appear under the IP Address check the box next to the IP address which indicated that is a current projector and we want the unit scanned for Status Refer to Figure 15 Once the SCAN button is depressed on the bottom right of the scan setting screen the following window will appear indicating the Control PC which is whe...

Page 18: ...ommunicating Please refer to the SAPS software manual for further information on these fields If the projector is not detected with the scan setting the following screen will appear under the All projector List Refer to Figure 18 Figure 18 At this point verify connection and S A P S menu options and contact your IT MIS department for assistance or Call 1 888 GO Sharp 1 888 467 4277 Option 2 Figure...

Page 19: ... analogy going using a dynamic IP address is similar to using a pay phone Unless there is a reason to receive a call the user does not care what number he or she is calling from Dynamic Host Configuration Protocol DHCP is a communications protocol that lets network administrators manage centrally and automate the assignment of Internet Protocol IP addresses in an organization s network Using the I...

Reviews: