30
VL-AD260U
6-3-6. Adjustment of audio circuit
1. Adjustment of filter f0
Measuring instrument
Oscilloscope
Mode
PB
Input signal (tape)
JiGWR5-5NSP
Measuring terminal
TL605/AUDIO OUT
Adjustment address
33
Set value
Clear the waveform
Audio Check
Checking of self-recording/playback
1) Input the audio signal (400Hz, -8dBs) into the Audio line IN/
OUT terminal, and record.
2) Connect the valve voltmeter (oscilloscope) to the Audio line
IN/OUT terminal.
3) Play back the record, and ascertain that the output waveform
level is -8 dBs
±
4 dBs (580 to 1370 mVp-p on the oscillo-
scope).
4) If there is any deviation from the specified value, perform
adjustment again as stated in items 1) above, and check again
the self-recording/playback level.
1) Set the alignment tape (JiGWR5-5NSP).
2) Using the adjustment remote controller (RRMCG0033TASA),
set the VCR adjustment mode, and set the address “33” with
the operation switch (FF/REWIND key).
3) Play back the standard tape.
4) Using the operation switch (FF/REWIND key), make an
adjustment so that the most clear playback waveform is
obtained on TL605.
5) Press the operation switch (PLAYBACK key) to write the
data.
6) Press the operation switch (STOP key) to exit from the
address “33”.
(The address “33” blinks.)
Measuring instrument
Valve Voltmeter (oscilloscope)
Mode
REC
→
PB
Input signal (tape)
400 Hz, -8 dBs (872 mVp-p)
Measuring terminal
Audio IN/OUT
Adjustment address
—
Set value
-8 dBs
±
4 dBs (580 to 1370 mVp-p)
2. Dac full-Scalle adjustment
Measuring point
TL1801 (G-OUT)
Address
039
Mode
VCR
Adjusting method
1) Set the data of address 082 changed to 80, address 0A2 changed to 00, address 0A5 changed to 80.
2) Connect TL3804 to P-CON 3.1V.
3) Connect the Digital voltmeter to TL801 and adjust the DC volt.
4) Set the data of address 082 changed to 40, address 0A2 28. (Restore)
Adjustment standard 0.78V
±
10mV
Remarks
———————
1. Inverter input Voltage Setting
6-3-7. Adjustment of LCD display circuit
Adjustment procedures and connections are the same as with the VCR section. (Refer to item 6-3-3)
3. R-W/B adjustment
Measuring point
TL3814 (LCD-VG) TL3813 (LCD-VR)
Address
090
Mode
VCR
Adjusting method
1) Set the data of address 082 at the address 80.
2) TL3814 (LCD-VG): Oscilloscope CH1
TL3813 (LCD-VR): Oscilloscope CH2
3) Adjust P-P of TL3813 becomes bigger 0.15V than TL3814.
4) Set the data of address 082 at the address 40. (Restore)
Adjustment standard
±
0.1Vp-p
Remarks
———————
G R
4. B-W/B adjustment
VCR ADJ
Address
Data(3.5 type)
50
95
51
90
52
74
Measuring point
TL3814 (LCD-VG) TL3815 (LCD-VB)
Address
092
Mode
VCR
Adjusting method
1) Set the data of address 082 at the address 80.
2) TL3814 (LCD-VG): Oscilloscope CH1
TL3815 (LCD-VB): Oscilloscope CH2
3) Adjust P-P of TL3815 become bigger 0.1V than TL3814.
4) Set the data of address 082 at the address 40. (Restore)
Adjustment standard
±
0.1Vp-p
Remarks
———————
Summary of Contents for VL-AD260U
Page 66: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 85 VCR PWB Wiring Side SIDE A ...
Page 68: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 87 VCR PWB Wiring Side SIDE B ...
Page 70: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 89 CAMERA PWB Wiring Side SIDE A ...
Page 72: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 91 CAMERA PWB Wiring Side SIDE B ...
Page 76: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 95 HEAD AMP PWB Wiring Side SIDE A ...
Page 77: ...VL AD260U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 96 HEAD AMP PWB Wiring Side SIDE B ...
Page 96: ...115 Ref No Part No Description Code Ref No Part No Description Code VL AD260U ...