VL-Z7S/E/Z7E-A/Z7E-W
VL-Z8H
3. DISASSEMBLY OF THE SET
3-1. Procedure for disassembling the cabinet
Note:
Before removing the cabinet, turn OFF the power and make sure that the battery is not connected.
1.
· Remove the screw ((s) XiPSF14P06000).
· Remove the shoe cover by sliding it frontward, remove the screw
((f) XiPSF17P04000) and remove the shoe terminal cover.
· Remove the screw ((b) XiPSN17P03000).
· Open the LCD panel 90 degrees and remove the two screws Z7S/
SA/R/E/EW/X/EEW/EWW/Z8H: ((x) LX-HZ0050TAFN) or Z7EEA/
EWA: ((n) LX-HZ0050TAFF).
· Remove the two screws Z7S/SA/R/E/EW/X/EEW/EWW/Z8H: ((c)
XiPSN17P04000) or Z7EEA/EWA: ((f) XiPSF17P04000) and
remove the KS camera front cover by pulling it frontward.
f
b
s
c
x
n
LCD panel
Shoe terminal cover
Shoe cover
KS camera front cover
or
x
n
or
f
or
c
f
or
2.
· Disconnect the connector of the KS camera front cover.
· Disconnect the two LCD tilt FPCs of the liquid crystal panel.
· Remove the two screws ((r) XiPSN20P08000) and remove the LCD
panel.
· Remove the screw Z7S/SA/R/E/EW/X/EEW/EWW/Z8H: ((p) LX-
HZ0063TAFN) or Z7EEA/EWA: ((z) LX-HZ0063TAFF) and screw
Z7S/SA/R/E/EW/X/EEW/EWW/Z8H: ((q) XiPSN17P06000) or
Z7EEA/EWA: ((m) XiPSF17P06000) that hold the camera L cabinet,
open the terminal cover and Z7S/SA/R/E/EW/X/EEW/EWW/Z8H:
remove the three screws ((b) XiPSN17P03000) or Z7EEA/EWA:
remove the one screw ((b) XiPSN17P03000) and the two screws
((e) XiPSF17P03000).
3.
· Disconnect the hot shoe FPC of the hot shoe and remove the
camera L cabinet.
· Remove the screw Z7S/SA/R/E/EW/X/EEW/EWW/Z8H: ((c)
XiPSN17P04000) or Z7EEA/EWA: ((f) XiPSF17P04000) and
remove the KS camera bottom cover.
· Disconnect the strobe FPC, remove the two screws ((a)
XiPSN17P02000) and remove the strobe unit.
å
Precautions in servicing the strobe unit
Once put in the card mode, the main condenser of the strobe
unit stays still electrically charged. If touching the strobe unit or
its nearby parts, you may get an electric shock.
To avoid this, connect a 7 k
Ω
resistor (300-V withstand voltage)
across the main condenser for about 10 seconds. The condenser
will be discharged.
r
r
p
b
b
q
Camera L cabinet
Connector
LCD tilt FPC
KS camera front cover
Terminal cover
LCD panel
m
or
e
or
b
e
or
z
or
a
a
KS camera bottom cover
Camera L cabinet
Strobe FPC
Strobe unit
Hot shoe FPC
c
f
or