39
VL-WD650U
10-2-4. Adjustment procedures
Item
Adjustment method
(1) Auto-focus adjustment
Set the unit to the auto-focus function adjustment mode and write data to the address "0000" one after another. This executed
the adjustments automatically. The items to be adjusted are as listed below. Every time an adjustment is made properly, the data
"FF" is written to the address. After each adjustment, make sure that the adjustment has been made properly, and then go on to
the next adjustment item.
Address
Data
Adjustment item
0000
0012
WIDE end adjustment
0006
WIDE end focus
∞
position adjustment
0008
TELE end focus
∞
position adjustment
000D
Zoom tracking adjustment
Note 1: To adjustment of
∞
position is executed by actually picking up the image of subject. For this adjustment use the subject with
clear profile.
Especially, if the adjustment of TELE end focus
∞
position is made without picking up the image of remote subject,
adjustment failure may occur.
Adjustment of WIDE end focus
∞
position: 3 m or more
Adjustment of TELE end focus
∞
position: 50 m or more
Note 2: In case of
∞
position adjustment the field depth is important to ensure the adjustment accuracy. If the field depth is high,
the focus becomes too stable , which may cause incorrect adjustment of
∞
position. Therefore the adjustment must be made
with low field depth (with iris opened).
The iris can be opened with the high-speed shutter.
1. It returns to the normal operation mode.
2. In the normal operation mode, set the high-speed shutter mode until the iris is opened. (Refer to the operation manual.)
3. Display “CAM ADJ” with the remote control for service.
4. It shifts to the auto-focus adjustment mode.
5. Perform the
∞
position adjustment.
6. After completing the
∞
position adjustment, return the high-speed shutter mode to the normal mode.
(2) Iris basic adjustment
This is for adjusting the operating point of the hole element installed in the iris meter of the lens.
The adjustment is automatically done by sequentially writing the data at the address "0000" in the camera signal system
adjustment mode.The items to be adjusted are as listed below. Every time an adjustment is made properly, the data "00FF" is
written to the address.
Address
Data
Adjustment item
0000
0009
Hall offset adjustment
000A
Iris offset adjustment
000B
Iris close adjustment
In the camera signal system adjustment mode (write the data " 00" to the address "0000"), set the unit to the
adjustment mode.
(3) Black balance adjustment/A/F noise adjustment
1)Prior to the adjustment, initialize the data for the addresses "0026", "0028", "002A", "002C", "002E", "0030".
Write " FF" to all of these address.
2) Write the data " 01" to the address "0001" This starts the adjustment automatically.
When the adjustment is completed properly, the data "00FF" is written automatically.
F
F
Summary of Contents for VIEWCAM VL-WD650U
Page 84: ...113 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE A ...
Page 86: ...115 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE B ...
Page 92: ...121 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE A ...
Page 94: ...123 VL WD650U Wiring Side SIDE B A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Page 102: ...131 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE A ...
Page 104: ...133 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE B ...
Page 106: ...135 VL WD650U Wiring Side SIDE A A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Page 107: ...136 VL WD650U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 Wiring Side SIDE B ...