36
VC-S2000HM
YES
YES
NO
NO
NO
NO
YES
YES
Replace capstan motor.
4-ii) Unusual sound in FF/REW mode
Is reel disk height as specified ?
Thrust gap found at reel disk ?
Drive system out of contact with any
part on main PWB ?
Turn capstan motor by hand.
Unusual sound heard ?
Check drive system’s gears for
damage. Replace damaged gear
with new one.
• Reel disk
• Limiter pulley ass’y
• Idler wheel ass’y
Check reel disk and main chassis.
And replace defective parts.
Adjust reel disk height.
Rearrange the parts on main PWB.
Summary of Contents for VC-S2000HM
Page 53: ...53 VC S2000HM 8 BLOCK DIAGRAM POWER CIRCUIT BLOCK DIAGRAM ...
Page 54: ...55 54 VC S2000HM VC S2000HM SYSTEM SERVO BLOCK DIAGRAM ...
Page 55: ...57 56 VC S2000HM VC S2000HM SIGNAL FLOW BLOCK DIAGRAM 1 2 ...
Page 56: ...59 58 VC S2000HM VC S2000HM SIGNAL FLOW BLOCK DIAGRAM 2 2 ...
Page 57: ...61 60 VC S2000HM VC S2000HM AUDIO BLOCK DIAGRAM ...
Page 66: ...76 1 2 3 4 5 6 7 8 9 10 A B C D E F G H I J VC S2000HM OPERATION R CIRCUIT ...
Page 79: ...76 1 2 3 4 5 6 7 8 9 10 A B C D E F G H I J VC S2000HM OPERATION R CIRCUIT ...
Page 80: ...57 56 VC S2000HM VC S2000HM SIGNAL FLOW BLOCK DIAGRAM 1 2 ...
Page 81: ...59 58 VC S2000HM VC S2000HM SIGNAL FLOW BLOCK DIAGRAM 2 2 ...
Page 82: ...55 54 VC S2000HM VC S2000HM SYSTEM SERVO BLOCK DIAGRAM ...
Page 83: ...53 VC S2000HM 8 BLOCK DIAGRAM POWER CIRCUIT BLOCK DIAGRAM ...
Page 84: ...61 60 VC S2000HM VC S2000HM AUDIO BLOCK DIAGRAM ...