36
VC-A422U
VC-H822U
MECHANISM TROUBLESHOOTING
1. FF/REW FAILURE (NO TAPE WINDING)
Press FF key.
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Y
ES
Is master cam at
FF position ?
Does loading
motor operate ?
Modes changing
smoothly through
cam switch ?
Loading motor
control system
in trouble.
Are Vco 12V and
Vcc 5V applied ?
Replace the
capstan motor.
Replace the idler
ass’y.
Replace the reel
sensor.
Is voltage applied
to loading motor ?
Loading motor is
damaged. Replace
it.
Voltage supply
system in trouble.
Mode sensor
system in trouble
or master cam
malpositioned.
Voltage supply
system in trouble.
Does capstan
motor turn in FF (or
REW) direction ?
Are idler wheel
ass’y and reel disk
in mesh ?
Is the pulse
outputted from reel
sensor ?
The cassette tape
is presumably
damaged.
2. REC/PLAY FAILURE (MODE RELEASE)
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
Is the master cam
at PB position ?
Does loading
motor operate ?
Modes changing
smoothly through
cam switch ?
Loading motor
control system
in trouble.
Are Vco 12V and
Vcc 5V applied ?
Replace the
capstan motor.
Replace the idler
ass’y.
Replace the reel
sensor.
Is voltage applied
to loading motor ?
Loading motor is
damaged. Replace
it.
Voltage supply
system in trouble.
Voltage supply
system in trouble.
Does capstan
motor turn ?
Are idler wheel
ass'y and reel disk
in mesh ?
Is the pulse
outputted from reel
sensor ?
Check main PWB.
Summary of Contents for VC-A422U
Page 51: ...VC A422U VC H822U VC A422U VC H822U 52 53 SIGNAL FLOW BLOCK DIAGRAM VC A422U ...
Page 52: ...VC A422U VC H822U VC A422U VC H822U 54 55 SIGNAL FLOW BLOCK DIAGRAM VC H822U ...
Page 53: ...56 VC A422U VC H822U POWER CIRCUIT BLOCK DIAGRAM ...
Page 63: ...72 VC A422U VC H822U M E M O ...
Page 76: ...85 VC A422U VC H822U M E M O ...