20
VC-A422U
VC-H822U
• Adjustment
1. If the indication of torque cassette meter is lower than
the setting, shift the tension spring engagement to the
part A.
2. If the indication of torque cassette meter is higher than
the setting, shift the tension spring engagement to the
part B.
• Checking the brake torque at the take-up side
Figure 4-22.
CCW: 4.9~13.7mN
⋅
m (50~140gf
⋅
cm)
CW:
3.9~10.8mN
⋅
m (40~110gf
⋅
cm)
• Remove the cassette housing control assembly.
• After short-circuiting between TP803 and TP802
provided at operation PWB, plug in the power cord.
• Setting
1. Switch from the FF mode to the STOP mode.
2. Disconnect the power cord.
3. Set a torque gauge to zero on the scale. Place it on the
take-up reel disk.
• Checking
1. Turn the torque gauge at a rate of about one turn/2 sec
in the CCW direction/CW direction so that the reel disk
and torque gauge pointer rotates at equal speed and
make sure that the value is within the setting (CCW
direction: 4.9 to 13.7mN·m (50 to 140gf·cm), CW direc-
tion: 3.9 to 10.8 mN·m (40 to 110gf·cm).
2. Adjustment of the brake torque at the supply side and the
take-up side
• Unless the supply side brake torque or take-up side
brake torque is within the setting, clean the felt surface
of reel disk (supply, take-up) brake lever, check again
the brake torque.
• If value cannot be set within the setting yet, replace the
main brake ass'y or main brake spring.
Figure 4-20.
4-14 CHECKING THE BRAKE TORQUE
• Checking the brake torque at the supply side
CCW: 2.9~9.8mN
⋅
m (30~100gf
⋅
cm)
CW:
4.9~13.7mN
⋅
m (50~140gf
⋅
cm)
Figure 4-21.
• Remove the cassette housing control assembly.
• After short-circuiting between TP803 and TP802
provided at operation PWB, plug in the power cord.
• Setting
1. Set a torque gauge to zero on the scale. Place it on the
supply reel disk.
2. Switch from the FF mode to the STOP mode.
3. Disconnect the power cord.
• Checking
Turn the torque gauge at a rate of about one turn/2 sec
in the CW direction/CCW direction with respect to the
supply reel disk so that the reel disk and torque gauge
pointer rotate at equal speed, and make sure that the
value is within the setting (CW direction: 4.9 to 13.7mN·m
(50 to 140gf·cm); CCW direction: 2.9 to 9.8mN·m (30 to
100gf·cm).
Tension arm
Tension spring
CW
CCW
CW
Supply reel disk
Torque gauge
Torque gauge
CCW
Take-up reel
disk
A
B
Summary of Contents for VC-A422U
Page 51: ...VC A422U VC H822U VC A422U VC H822U 52 53 SIGNAL FLOW BLOCK DIAGRAM VC A422U ...
Page 52: ...VC A422U VC H822U VC A422U VC H822U 54 55 SIGNAL FLOW BLOCK DIAGRAM VC H822U ...
Page 53: ...56 VC A422U VC H822U POWER CIRCUIT BLOCK DIAGRAM ...
Page 63: ...72 VC A422U VC H822U M E M O ...
Page 76: ...85 VC A422U VC H822U M E M O ...