5
SJ-P58M
SJ-P63M
SJ-P68M
Common
Main coil
Aux. coil
LIST OF ELECTRICAL PARTS
ITEMS
TYPE NAME
RATING
SPECIFICATIONS
Thermostat
MM1-8123
125V 6A
(At normal notch)
250V 3A
ON/OFF : -19/-24˚C
Defrost thermostat
S101
250V 8A
Open/Close : 10/1˚C
Thermo. fuse
SF70E
250V 10A
Working temp. : 70˚C
F-fan motor
3R00044B
220-240V 50/60Hz
Working with ø100 fan
R-fan motor
3R00122A
220-240V 50/60Hz
Working with ø80 fan
(R-fan fuse)
123
250V 2A
Cut OFF 130˚C
Defrost heater
MM6-4198
220-240V 353
Ω
150W at 230V
Door switch
DSD-5
250V 0.25A
4 terminals push-button type
Damper thermostat
MM1-6176
—
Open/Close : 2/-3˚C
Defrost timer
ND1004M2
220-240V
Integration type
50/60Hz
Cycle time : 10.8/9.0 hours(50/60Hz)
Delay time : 4.3/3.6 min.(50/60Hz)
Lamp socket (F/R)
—
250V 1A
E-12(Hard plastic body type)
F-lamp
—
240V 10W
E-12
R-lamp
—
240V 15W
E-12
R-fan thermo. R-fan thermo.
S101
250V 8A
Open/ Close : 7/15˚C
ass'y R-fan thermo.heater
RSS2
350V, 2W, 10k
Ω
1.1W at 230V
Compressor
FGS130HAW
220-240V/50Hz
Cooling capacity : 316W (50Hz)
Main coil : 7.9
Ω
Aux. coil : 13.7
Ω
(at 25˚C)
Starting relay
PTH8M220MD2
—
15
Ω
(at 25˚C)
Overload relay(Protector)
4TM283RFBYY
—
Open/ Close : 130˚C / 61˚C
Running capacitor
—
5
µ
F,430V
—
Ionizer-K(Plasmacluster unit)
FTRN-A014CBKZ
DC 12V
3.5kV p-p