6
SJ-48G/D48G
SJ-51G/D51G
SJ-55G/D55G
LIST OF ELECTRICAL PARTS
DESTINATION: R,M,Y,T
Items
SJ-48G, SJ-D48G
SJ-51G, SJ-D51G, SJ-55G, SJ-D55G
Source
220/230/240V 50Hz
Climate class
T, ST
Thermostat
Type: MM1-8025 ON: –17±5˚C OFF: –22±1.5˚C(at normal notch)
Damper thermostat
Type: MM1-6129
Baffle opened 1.5˚C(at normal notch)
Baffle closed –3±1.5˚C
Timer
Type: TMDF904FD2, Integration type
Cycle 10hours 50 min., Working time about 4min. 20sec. 50Hz
Fuse ass'y
Thermo. fuse Type: SF70E 250V 10A Working temp. 70±2˚C
or MTG4A50072 250V 10A Working temp. 72±2˚C
Defrost thermostat
Type: US602S 250V 8A OPEN 10±3˚C CLOSE 1±3˚C
Door switch
3 terminals push-button 250V 0.25A
Lamp socket
250V 1A E-12(HARD PLASTIC BODY TYPE)
Lamp
240V 10W E-12
Fan motor
Type: MH15SAF-TJA7 200/240V 50Hz
Compressor
Type: GL-90BH
Type: GL-99BH
50Hz(OIL COOLING)
50Hz(OIL COOLING)
Cooling capacity 223W
Cooling capacity 244W
Main coil 8.8Ω
Main coil 8.5Ω
Aux. coil 17.7Ω(at 20˚C)
Aux. coil 15Ω(at 20˚C)
Terminal
Terminal
Starting relay
PTC/UH-3003 14Ω 350V
Overload relay(Protector)
4TM276NFBYY OFF 120˚C ON 61˚C
4TM308NFBYY OFF 120˚C ON 61˚C
Running capacitor
6µF / 400V
Defrost heater
220V 137.1W / 230V 150W / 240V 164.9W 353Ω
Aux. coil
Common
Main coil
Aux. coil
Common
Main coil