2
SJ-48G/D48G
SJ-51G/D51G
SJ-55G/D55G
OUTLINE OF PRODUCT
(Comparison between Type G and Type E)
G type
E type
Cooling Unit
Refrigerant
CFC-12
Outer dimensions
(Height
~
Width
~
Depth)
Heat insulator
48G
@
1620
~
735
~
700(mm)
@@@
(63.8"
~
28.9"
~
27.6")
51G
@
1700
~
735
~
700(mm)
@@@
(66.9"
~
28.9"
~
27.6")
55G
@
1820
~
735
~
700(mm)
@@@
(71.7"
~
28.9"
~
27.6")
42E
@
1620
~
715
~
690(mm)
@@@
(63.8"
~
28.1"
~
27.2")
45E
@
1735
~
715
~
690(mm)
@@@
(68.3"
~
28.1"
~
27.2")
50E
@
1825
~
715
~
690(mm)
@@@
(71.9"
~
28.1"
~
27.2")
Rated storage volume
48G
@
443 liter(15.6cu.ft.)
@@@
F:139(4.9) R:304(10.7)
51G
@
483 liter(17.1cu.ft.)
@@@
F:139(4.9) R:334(11.8)
55G
@
521 liter(18.4cu.ft.)
@@@
F:139(4.9) R:382(13.5)
42E
@
400 liter(14.2cu.ft.)
@@
F:98(3.5) R:302(10.7)
45E
@
430 liter(15.2cu.ft.)
@@
F:128(4.5) R:302(10.7)
50E
@
470 liter(16.6cu.ft.)
@@
F:162(5.7) R:308(10.9)
Specifications of interior
Fresh case
0
2
Chilled case
1
0
Three position
adjustable shelf
1
0
Polyurethane foam that uses
CFC-11
Conforms to the Regulations for Specific CFCs that will take effect in 1996.
HFC-134a
Polyurethane foam that uses
cyclopentane