OPERATIONS

LED DISPLAY

•  It indicates the blower power level by number.

BLOWER CONTROL

•  Tap the + blower control; the backlight of button will turn 

on, the blower starts to work on low speed and the LED 

display shows 1.

•  Tap it another time; the blower will reach medium speed and 

LED display shows 2.

•  Tap it another time; the blower will reach high speed and the 

LED display shows 3.

•  (For 600 CFM models – SHC3062FS and SHC3662FS) Tap 

again; the blower will reach the boost mode and the LED 

display will show 4. The motor will run for 10-minutes and 

then automatically decrease to high speed and the LED 

display will show 3.

•  Tap the – blower control; the backlight of button will be 

on, the blower speed will decrease one speed and the LED 

display will show the current working speed.

•  When the blower is set on low speed (1), tapping it another 

time will turn off the blower (as well as the backlight of 

the – blower control).

15-MINUTE DELAY

•  While the blower is on, tap it once (its back light will turn on) 

to get the hood running for 15 minutes and then automatically 

turn off blower and lights.

•  To  cancel  the  delay  off  function  before  the  end  of  the 

15-minute cycle, tap it again or change the blower speed by 

one of blower control buttons (+ or -). The backlight of the 

15-minute delay button will then turn off.

POWER ON/OFF

•  Tap once; the back light of the button will turn on, the blower 

will work on low speed and light will be on, too.

•  Tap another time; the blower and the light will turn off as 

well as all backlights.

CAP (CFM ADJUSTABLE PLATFORM) SETTING 
(SHC3062FS & SHC3662FS ONLY)

In case the blower power (CFM = Cubic Feet per Minute) shall be 

limited due to state or local “Makeup Air” regulations, the CFM 

can be adjusted to a lower level to comply with the regulations. 

There are two different CFM adjustments settings; 1) maximum 

CFM <300 CFM and 2) maximum CFM <400 CFM. Please 

adjust the CFM properly by following the instruction below.

Hold the – and + blower controls for 5 seconds, the backlights 

of the – and + blower control buttons will illuminate, and 

an audible 3 short beeps; the LED display will show B. The 

range hood is changed to 400 CFM setting mode.

Hold the – and + blower controls for 5 seconds, the backlights 

of the – and + blower control buttons will illuminate, and 

an audible 5 short beeps; the LED display will show C. The 

range hood is changed to 300 CFM setting mode.

  The PCB will have memory function. The above setting must 

be set before end user starts to use. And after then, even if 

the range hood has an electrical breakdown, the speed setting 

mode will be unchanged.

CONTROL PANEL

LED 

DISPLAY

BLOWER

CONTROLS

LIGHT

ON/OFF

POWER

ON/OFF

15 MINUTE

DELAY

Summary of Contents for SHC2432FS

Page 1: ...C3062FS SHC3662FS OPERATION MANUAL INSTALLATION INSTRUCTIONS Sep 28 2020 CUSTOMER ASSISTANCE 2 CONSUMER LIMITED WARRANTY 3 BEFORE INSTALLING THE RANGE HOOD 4 RANGE HOOD DIMENSIONS 5 RANGE HOOD MAIN PARTS 6 MEASURE THE INSTALLATION 8 INSTALLATION INSTRUCTIONS 9 OPERATIONS 15 CLEANING MAINTENANCE 16 TROUBLE SHOOTING 17 ...

Page 2: ...r Request Service Æ Purchase an Extended Warranty Æ Downloads including the Installation Guide Spec Sheet and Owner s Manual CONTACT US If at any time you have questions or comments concerning your SHARP product please contact the SHARP Customer Assistance Center We are available to assist you through multiple contact methods for your convenience Scan this QR Code on your mobile device Visit http ...

Page 3: ...in shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser Correction of defects in the manner and for the period of time described herein shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims wh...

Page 4: ... allowed to accumulate on fan or filters 4 Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIAT...

Page 5: ...5 19 11 16 23 9 16 29 1 2 35 1 4 Max 40 3 8 8 3 4 6 25 32 1 3 8 9 21 32 Min 25 3 8 RANGE HOOD DIMENSIONS ...

Page 6: ...Flue Mounting Bracket 1 Hood Mounting Bracket 2 Aluminum Grease Filters for a 30 hood 3 Aluminum Grease Filters for a 36 hood 1 Installation Manual 1 Parts Bag containing 6 Mounting Screws no 8 x 3 8 Pan Head 7 Mounting Screws no 8 x 11 2 Flat Head 7 Drywall Anchors 2 Washers U Upper Flue Mounting Bracket pper Flue Mounting Bracket Lower Flue Mounting Bracket Lower Flue Mounting Bracket Decorative...

Page 7: ...CFM 350 CFM 350 CFM Speed 3 350 CFM 450 CFM 470 CFM 470 CFM Speed 4 600 CFM 600 CFM Delay off 15 minutes Control Complement Capacitive Touch Control with LED display Bower Speed Adjustment Light Hi Low Off Delay Off Master Power ON OFF Safety Standard ETL Listed Net Weight Approx 23 lbs Approx 23 lbs Approx 24 lbs Approx 26 lbs AVAILABLE ACCESSORY PARTS NUMBERS RANGE HOOD NON DUCT KIT CHARCOAL FIL...

Page 8: ...ommended for best capture of cooking impurities Distances over 36 are at the installer and users discretion providing that the ceiling height permits SIDE VIEW 9 3 4 WALL CAP HOOD DECORATIVE FLUE ROOF CAP 6 ROUND DUCT ROUND ELBOW 10 5 8 TO CENTER OF BRACKET HOLES HOOD MOUNTING BRACKET 3 3 8 DUCT CENTER LINE 26 36 ABOVE COOKING SURFACE ...

Page 9: ...ee illustration below Pins on top DAMPER ADAPTER PREPARATION FOR SHC2432FS Damper is packed in side carton separately Use four Mounting Screws no 8 x 3 8 Pan Head to fix the damper as shown in the picture below Damper INSTALL THE WIRING 4 22 11 LOCATE ELECTRICAL OUTLET WITHIN THESE AREAS Verify location will not interfere with duct mounting brackets and flue HD1250A GROUNDING INSTRUCTIONS This app...

Page 10: ...ance above cooktop must not be less than 24 Distances over 36 above the cooktop are at the installer s and user s discretion providing that ceiling height and flue length permit MOUNTING BRACKET LOCATION ABOVE 36 HIGH COOKTOP NOTE On 8 ft ceilings Hood distance above cooktop is Minimum 26 Maximum 34 for ducted discharge Minimum 26 Maximum 31 for non ducted discharge On 9 ft ceilings Hood distance ...

Page 11: ...upright 14 MAX LOWER FLUE MOUNTING BRACKET HD1222A INSTALLATION INSTRUCTIONS 5 To make sure there will be adequate clearance between top of hood and lower flue mounting bracket for ductwork Elbow must be located below lower flue mounting bracket 6 Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket HD1223 SIDE VIEW INSIDE BACK OF...

Page 12: ... HOODS ONLY 1 DO NOT REMOVE the protective plastic film covering the decorative flue and the hood at this time 2 Lay the back side of the hood flat on a table Use a piece of cardboard to avoid damaging the table or the hood 3 Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove 4 Carefully rotate hood upright HD1179 LOWER FLUE MOUNTING BRACKET LOWER ...

Page 13: ...to the upper flue mounting bracket using 2 no 8 x 3 8 mounting screws 15 Remove protective plastic film covering the upper flue and the hood INSTALL THE HOOD NON DUCTED HOODS ONLY Non ducted installation requires a Non Duct kit for your model which is separately sold AVAILABLE ACCESSORY PARTS NUMBERS RANGE HOOD NON DUCT KIT CHARCOAL FILTERS EXTENSION FLUE SHC2432FS SKCH32DLK SKCH32CFL SKCH62EXF SH...

Page 14: ... holes located in the inside lower back of hood using a 5 16 drill bit Insert the included drywall anchors into the drilled holes one for each hole Install 2 washers and 2 no 8 x 1 mounting screws through the back of the hood and into the drywall anchors Verify that the hood is centered and leveled Tighten all screws completely 14 Attach 2 two non duct recirculation filters to sides of blower by a...

Page 15: ...ttons or The backlight of the 15 minute delay button will then turn off POWER ON OFF Tap once the back light of the button will turn on the blower will work on low speed and light will be on too Tap another time the blower and the light will turn off as well as all backlights CAP CFM ADJUSTABLE PLATFORM SETTING SHC3062FS SHC3662FS ONLY In case the blower power CFM Cubic Feet per Minute shall be li...

Page 16: ...ranty Remove grease filters by pulling down on the metal latch tab This will disengage the filter from the hood Tilt the filter downward and remove NON DUCTED RECIRCULATION FILTERS The non ducted recirculation filters should be changed every 6 months Replace more often if your cooking style generates extra grease such as frying and wok cooking Turn the filter mounting tabs to remove filter and rep...

Page 17: ...ith sealant Leakage from the connection of chimney and cover Take chimney down and seal Lights not working Broken or faulty bulbs Replace bulbs as per this instruction Insufficient suction The distance between the range hood and the gas top is too far Refit the range hood to the correct distance The Range hood inclines The fixing screw is not tight enough Tighten the hanging screw and make it hori...

Page 18: ......

Page 19: ...19 ...