PROCEDURE
LETTER
COMPONENT TEST
CARRY OUT 4R CHECKS
ASYMMETRIC RECTIFIER TEST
CARRY OUT 3D CHECKS.
Isolate the high voltage rectifier assembly from the HV circuit. The asymmetric rectifier can be tested
using an ohmmeter set to its highest range. Connect the ohmmeter across the terminals A + B of the
asymmetric rectifier and note the reading obtained. Reverse the meter leads and note this second
reading. If an open circuit is indicated in both directions then the asymmetric rectifier is good. If an
asymmetric rectifier is shorted in either direction, then the asymmetric rectifier is faulty and must be
replaced along with the high voltage rectifier. When the asymmetric rectifier is defective, check whether
the magnetron, high voltage rectifier, high voltage wire or filament winding of the power transformer is
is also damaged.
CARRY OUT 4R CHECKS
NOTE: FOR MEASURING THE RESISTANCE OF THE RECTIFIER, THE BATTERIES OF THE
MEASURING INSTRUMENT MUST HAVE A VOLTAGE OF AT LEAST 6 VOLTS, BECAUSE
OTHERWISE AN INFINITE RESISTANCE MIGHT BE SHOWN IN BOTH DIRECTIONS.
A
B
C
CARRY OUT 3D CHECKS
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest resistance
range.
C. A normal capacitor shows continuity for a very short time (kick) and then a resistance of about 10 M
Ω
after it has been charged.
D. A short-circuited capacitor shows continuity all the time.
E. An open capacitor constantly shows a resistance about 10 M
Ω
because of its internal 10 M
Ω
resistance.
F. When the internal wire is opened in the high voltage capacitor, the capacitor shows an infinite
resistance.
G. The resistance across all the terminals and the chassis must be infinite when the capacitor is normal.
If incorrect readings are obtained, the high voltage capacitor must be replaced.
CARRY OUT 4R CHECKS
D
HIGH VOLTAGE CAPACITOR TEST
E
SWITCH TEST
CARRY OUT 3D CHECKS
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the
following table.
COM;
Common terminal
NO;
Normally open terminal
NC;
Normally close terminal
Table: Terminal Connection of Switch
Plunger Operation
COM to NO
COM to NC
Released
Open circuit
Short circuit
Depressed
Short circuit
Open Circuit
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.
A
B
C
D2
D1
ASYMMETRIC
RECTIFIER
HIGH VOLTAGE RECTIFIER