R-580D
18
24
P25
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cook-
ing and "H" level while not cooking. In other
cooking modes (variable cooking) the signal
turns to "H" level and "L" level in repetition
according to the power level.
(ON and OFF times for other power level.)
25
P26
OUT
Back light (Light emitting diodes) circuit driving signal.
26
P27
OUT
Terminal not used.
27-29
P30-P32
OUT
Terminal not used.
30-34
P33-P37
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
35
CVCC
IN
Power source voltage: GND(0V).
The power source voltage to drive LSI is input to CVCC terminal. Connected to GND.
36
VSS
IN
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC.
37-38
V3-V2
IN
Terminal not used.
39-40
V1-V0
IN
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
41
VCC
IN
Power source voltage : GND(0V).
The power source voltage to drive LSI is input to VCC terminal.
42-45
COM4-COM1
OUT
Terminal not used.
46-65
SEG1-SEG20
OUT
Terminal not used.
66-69
P74-P77
OUT
Data output terminal to LCD driver IC3.
70-77
P80-P87
OUT
Data output terminal to LCD driver IC3.
78-79
P90-P91
OUT
Data output terminal to LCD driver IC3.
80-85
SEG35-SEG40
OUT
Terminal not used.
86-88
P40-P42
OUT
Terminal not used.
89
IRQ0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
90
AVCC
IN
A/D converter power source voltage : GND(0V).
The power source voltage to drive the A/D converter. Connected to GND.
91
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
92
AN1
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
93
AN2
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
94
AN3
IN
Connected to VC through the pull-down resistor.
95-98
AN4-AN7
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
99
AN8
IN
Signal similar to ANI7.
When either G12 line on key matrix is touched, a corresponding signal will be input into
AN8.
100
AN9
IN
Signal similar to ANI7.
When either G12 line on key matrix is touched, a corresponding signal will be input into
AN9.
Pin No.
Signal
I/O
Description
HIGH
H : GND
L : -5V
H : GND
L : -5V
M.HIGH
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
20.0 msec.
H : GND
L : -5V
Summary of Contents for R-580D