25
R -540DK
R-540DW
ABSOLUTE HUMIDITY SENSOR CIRCUIT
(1) Structure of Absolute Humidity Sensor
The absolute humidity sensor includes two thermistors
as shown in the illustration. One thermistor is housed in
the closed vessel filled with dry air while another in the
open vessel. Each sensor is provided with the protective
cover made of metal mesh to be protected from the
external airflow.
(2) Operational Principle of Absolute Humidity Sensor
The figure below shows the basic structure of an
absolute humidity sensor. A bridge circuit is formed by
two thermistors and two resistors (R1 and R2).
The output of the bridge circuit is to be amplified by the
operational amplifier.
Each thermistor is supplied with a current to keep it
heated at about 150˚C (302˚F), the resultant heat is
dissipated in the air and if the two thermistors are
placed in different humidity conditions they show
different degrees of heat conductivity leading to a
potential difference between them causing an output
voltage from the bridge circuit, the intensity of which is
increased as the absolute humidity of the air increases.
Since the output is very minute, it is amplified by the
operational amplifier.
(3) Detector Circuit of Absolute Humidity Sensor Circuit
This detector circuit is used to detect the output voltage
of the absolute humidity circuit to allow the LSI to
control sensor cooking of the unit. When the unit is set
in the sensor cooking mode, 16 seconds clearing cycle
occurs than the detector circuit starts to function and
the LSI observes the initial voltage available at its AN6
terminal.
With this voltage given, the switches SW1 to SW5 in the
LSI are turned on in such a way as to change the
resistance values in parallel with R47 ~ R52. Changing
the resistance values results in that there is the same
potential at both F-3 terminal of the absolute humidity
sensor and AN5 terminal of the LSI. The voltage of AN6
terminal will indicate about +2.5V. This initial balancing
is set up about 16 seconds after the unit is put in the
Sensor Cooking mode. As the sensor cooking proceeds,
the food is heated to generate moisture by which the
resistance balance of the bridge circuit is deviated to
increase the voltage available at AN6 terminal of the
LSI.
Then the LSI observes that voltage at AN6 terminal and
compares it with its initial value, and when the
comparison rate reaches the preset value (fixed for
each menu to be cooked), the LSI causes the unit to
stop sensor cooking; thereafter, the unit goes in the
next operation automatically.
The LSI starts to detect the initial voltage at AN6
terminal 16 seconds after the unit has been put in the
Sensor Cooking mode. If it is not possible to balance
the bridge circuit due to disconnection of the absolute
humidity sensor, ERROR will appear on the display and
the cooking is stopped.
1) Absolute humidity sensor circuit
Sensing part
(Open vessel)
Sensing part
(Closed vessel)
Thermistors
ventilation opening for sensing
S
C
R3
R1
R2
+
Operational
amplifier
Output
voltage
S : Thermistor
open vessel
C : Thermistor
closed vessel
2
Absolute humidity (g/m )
Output voltage
Absolute humidity vs,
output voltage characteristic
R43 1.8K
VA : +15V
VC : +5V
R42 3.57K
R41 3.32K
S
C
R47 47K
R48 620K
R49 300K
R50 150K
R51 75K
R52 37.4K
R44 360K
R45 10K
3
F2
8
4
1
2
IC3
+
-
R40 330
C40 0.1
µ
F
D40
R46 47K
86
PA4
PA3
PA2
PA1
PA0
AN5
SW1
SW2
SW3
SW4
SW5
AN6
LSI
(IC1)
85
95
96
97
98
99
C41 0.015
µ
F
C. Thermistor in
closed vessel
S. Thermistor in
open vessel
C42 0.01
µ
F
C43 0.01
µ
F
F3
F1