22
R-4A68
Note:
The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of
microwave energy from oven cavity during cook
cycle. This function does not require that door be air-
tight, moisture (condensation)-tight or light-tight.
Therefore, occasional appearance of moisture, light
or sensing of gentle warm air movement around
oven door is not abnormal and do not of themselves,
indicate a leakage of microwave energy from oven
cavity.
UPPER
OVEN HINGE
PIN
DDOR PANEL
CHOKE
COVER
PIN
LOWER
OVEN
HINGE
Figure C-5. Door Replacement
SEALER FILM
Installation
1. Put the adhesive tape on the backing film of the sealer
film.
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the sealer film on the door panel.
Sealer film
Backing film
Adhesive tape
Sealer Film
DOOR REPLACEMENT
REMOVAL
1. Disconnect oven from power supply.
2. Push the open button and open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the
gap between the choke cover and corner portion of door
panel as shown in Figure C-5 to free engaging parts.
4. Try the principles of the lever and lift up the choke cover
by inserting a putty knife in the order shown in Figure C-
5.
5. Release choke cover from door panel.
6. Now choke cover is free.
Putty Knife
Door frame
Choke Cover
12
11
10
9
8
7
6
5
4
3
2
1
Figure C-5. Door Disassembly
7. Release two (2) pins of door panel from two (2) hole of
upper and lower oven hinges by lifting up.
8. Now, door assemblyl is free from oven cavity.
RE-INSTALL
1. Catch two (2) holes of door panel on two (2) hole of upper
and lower door hinges.
2. Re-install choke cover to door panel by pushing.
Note: After any service to the door;
(A) Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Microwave
Measurement Procedure.)