23
R-430CK
R-430CW
R-430CD
24
P25
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "L" level in repetition according to the
power level.
(ON and OFF times for other power level.)
25-26
P26-P27
OUT
Terminal not used.
27-29
P30-P32
OUT
Terminal not used.
30-34
P33-P37
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
35
CVCC
IN
Connected to GND.
36
VSS
IN
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC
37-38
V3-V2
IN
Terminal not used.
39-40
V1-V0
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
41
VCC
IN
Power source voltage: GND (0V).
The power source voltage to drive the LSI is input to VCC terminal.
42-45 COM4-COM1 OUT
Terminal not used.
46-65 SEG1-SEG20 OUT
Terminal not used.
66-79
P74-P91
OUT
Data output terminal to LCD driver IC3
80-85
SEG35-SEG40
OUT
Terminal not used.
86
P40
OUT
Terminal not used.
87
P41
IN
Signal similar to AN10.
When either G13 line on key matrix is touched, a corresponding signal will be input into P41.
88 P42
INSignal similar to AN10.
When either G12 line on key matrix is touched, a corresponding signal will be input into P42.
89
IRQ0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
90
AVCC
IN
A/D converter power source voltage.
The power source voltage to drive the A/D convertor built into LSI. connected to GND.
91
AN0
IN
Used for initial balancing of bridge circuit (absolute humidity sensor). This input is an
analoge input terminal from the AH sensor circuit, and connected to the A/D converter
built into the LSI.
92
AN1
IN
AH sensor input.
This input is an analoge input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
Pin No.
Signal
I/O
Description
P-HI
H : GND
L : -5V
H : GND
L : -5V
P-70
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
16.7 msec.
H : GND
L : -5V