For example: Procedure to check the total cooking number of times (example, 957700 times) and using time (example, 1260 hours) of MG 1
and set 0 hours after MG1 is replaced.
: no sound
: 0.1 second sound : 2.0 second sound : (0.06 sec. ON, 0.06 sec. OFF) x 2 beeps
✩
: [(0.04 sec. ON, 0.04 sec. OFF) x 3] x 4 beeps
: (0.1 sec. ON, 0.1 sec. OFF) x 10 beeps
For example: Procedure to check the total cooking number of times (example, 957700 times) and clear it and check using time (example,
1260 hours) of MG 1 and set the using time (example, 1000 hours) of MG1.
For example : Procedure to change the limit time of magnetron from 3800 hours to 4000 hours if need. The timing that CC1 or CC2 is shown
in the display can be changed.
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
2
(after 1 sec.)
1
MANUAL/ REPEAT
START
STOP/CLEAR
CHECK
CHECK
0
0
0
0
SF-
SF2
9577
(total counter for serviced [x 100])
1260
0
SF-2
0
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
2
(after 1 sec.)
MANUAL/ REPEAT
START
1
MANUAL/ REPEAT
1,0,0,0
START
STOP/CLEAR
CHECK
CHECK
0
0
0
0
SF-
SF2
9577
(total counter for serviced [x 100])
0
SF-2
1260
0
1000
SF-2
0
x4
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
2
(after 1 sec.)
9
MANUAL/ REPEAT
2,0,0,0
START
STOP/CLEAR
CHECK
CHECK
0
0
0
0
SF-
SF2
9577
(total counter for serviced [x 100])
3800
0
4000
SF-2
0
x4