SJF800SPSL
9 – 2
• Buzzer:
=0.5 sec ON/0.5 sec OFF,
=2 sec ON/0.5 sec OFF
No
.
Status
Buzzer
LCD
Display
Content
Correspon-
dence
method
-
No defects
None
- - - -
1
F-thermistor system defect
EE 01
Defect of each thermistor, short circuit/wire breakage of ther-
mistor wiring and defect of main PWB
→
[1]
2
R-thermistor system defect
EE 02
→
[2]
3
DEF-thermistor system defect
EE 03
→
[3]
4
Outside temperature-thermistor
system defect
EE 04
→
[4]
5
Defrost defect
EE 07
Wire breakage of fuse•defrost heater, defect of main PWB
(120-minute defrosting has been occurred continuously 2 times
within the past 48 hours.)
→
[5]
6
F fan motor system defect
EE 08
Defect of each fan motor, fan-lock and defect of wiring/main
PWB
(When fan motor is ON, over current or no current is detected.)
→
[6]
7
C fan motor system defect
EE 09
→
[7]
8
R fan motor system defect
EE 10
→
[8]
9
Ionizer (Plasmacluster) system
defect
EE 11
→
[9]
10
LCD Display communication defect
EE 12
Short circuit/wire breakage of wiring and defect of LCD or main
PWB (Communication with LCD PWB has been abnormal over
3 times within the past 48 hours.)
→
[10]
11
F-thermistor system defect history
EH 61
Defect of thermistor system has been occurred over 1 minute
continuously within the past 48 hours.
→
[1]
12
R-thermistor system defect history
EH 62
→
[2]
13
DEF-thermistor system defect his-
tory
EH 63
→
[3]
14
Outside temperature-thermistor
system defect history
EH 64
→
[4]
15
F fan motor system defect history
EH 66
Defect of fan motor has been occurred over 3 times continu-
ously within the past 48 hours.
→
[6]
16
C fan motor system defect history
EH 67
→
[7]
17
R fan motor system defect history
EH 68
→
[8]
18
Ionizer (Plasmacluster) electrifying
defect history
EH 72
Defect of Ionizer (Plasmacluster) electrifying has been
occurred over 3 times continuously within the past 48 hours.
→
[9]
19
F-room high temperature history
EH 76
Temperature of F-thermistor has been reached over -10
°
C con-
tinuously for 6 hours or more within the past 48 hours. (except
right after the installation)
→
[1]
20
R-room high temperature history
EH 77
Temperature of R-thermistor has been reached over +10
°
C
continuously for 6 hours or more within the past 48 hours.
(except right after the installation)
→
[2]
Summary of Contents for Plasmacluster SJ-F800SPBK
Page 12: ...SJF800SPSL 7 2 2 ELECTRIC ACCESSORIES LAYOUT ...
Page 16: ...SJF800SPSL 8 4 6 CIRCUIT DIAGRAM OF MAIN PWB ...
Page 17: ...SJF800SPSL 8 5 7 CIRCUIT DIAGRAM OF LCD PWB ...
Page 40: ...SJF800SPSL 12 1 SJF800SPSL Service Manual CHAPTER 12 COOLING UNIT 1 COOLING UNIT ...
Page 42: ...SJF800SPSL 12 3 ...