- 5 - Installation Manual for PV modules
B) MODULE SPECIFIC INSTRUCTIONS
ND-123UJF / ND-130UJF
MECHANICAL INSTALLATION
Please review the descriptions below and drawings carefully; not
mounting the modules according to the described method may void
your warranty. Additionally, UL has tested and listed these modules for
mounting using bolts.
Mounting Using Frame Bolt Holes (Figure 10 & 11)
The modules may be fastened to a support using the bolt holes in the
bottom of the frame at location “C”, as shown in Figure 11 (back view
of the module) and Figure 10 (mounting detail). The module should be
fastened with four (4) M8 (5/16”) bolts. The mounting method is
designed to withstand loads of 2400 Pa. Take care during installation
to not block the drain holes (D) shown in Figure 11.
D
D
D
D
C
C
C
C
D
C) ELECTRICAL INFORMATION
ELECTRICAL RATINGS
Rated electrical characteristics are within ±10 percent of the indicated values of Isc, Voc and 10/-5 percent of Pmax under Standard Test
Conditions (irradiance of 100 mW/cm
2
, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in
this manual.
ND-123UJF ND-130UJF
Maximum Power (Pmax)
123.0 W
130.0 W
Open-Circuit Voltage (Voc)
21.78 V
21.90 V
Short-Circuit Current (Isc)
7.99 A
8.20 A
Voltage at maximum power (Vpmax)
17.21 V
17.40 V
Current at maximum power (Ipmax)
7.15 A
7.50 A
Maximum System Voltage
600 V
600 V
Minimum Blocking diode
15 A
15 A
Maximum Series Fuse
15 A
15 A
Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values
of Isc and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor
ampacities, fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electric Code for an additional
multiplying factor of 125 percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in
accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1.
Figure 10
Figure 11
WASHER
BOLT M8 X 20mm
SOLAR MODULE
WASHER
SPRING WASHER
NUT
WASHER
BOLT M8 X 20mm
SOLAR MODULE
WASHER
SPRING WASHER
NUT
BOLT M8 X 20 mm
WASHER
BOLT M8 X 20mm
SOLAR MODULE
WASHER
SPRING WASHER
NUT
WASHER
BOLT M8 X 20mm
SOLAR MODULE
WASHER
SPRING WASHER
NUT
BOLT M8 X 20 mm