MX-EB12N Mirroring Kit
32
SHARP
Document Solution Centre
Troubleshooting:
Case
Trouble
Cause
Advice
A
One HDD status
is OK.
One HDD status is
NG
Connection failure of the
connectors and harness of the
mirroring kit
x
Replace the HDD & perform the replacement
procedure of the mirroring kit HDD.
x
Replace the mirroring kit and perform the
replacement procedure of the mirroring kit
HDD.
B
When at least one
HDD is OK.
x
Communication trouble
through the SATA harness of
HDD.
x
Trouble of HDD which
indicates the status other than
OK.
x
Broken data in HDD.
x
RAID PWB trouble.
x
Replace the cable. Remove and connect.
x
Replace the HDD which indicates other than
OK and perform the replacement procedure
of the mirroring kit HDD or standard machine
HDD.
x
Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
C
When at least one
HDD is NONE.
x
Communication trouble
through the SATA harness of
HDD.
x
Connection failure between
the mirroring kit and the HDD.
x
HDD trouble.
x
HDD SATA harness &
connector trouble.
x
RAID PWB trouble.
x
Replace the cable. Remove and connect.
x
Check connection between the mirroring kit
and the HDD.
x
Replace the HDD which indicates NONE.
Perform the replacement procedure of the
mirroring kit HDD or standard machine HDD.
x
Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
x
Replace both of the HDD of the mirroring kit
and that of the machine.
D
When in TROUBLE-
TROUBLE.
x
RAID PWB trouble
x
(Both or one) HDD trouble
x
Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
x
Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
E
When in TROUBLE-
TROUBLE.
(Occurring when
replacing the HDD)
x
The mirroring kit is composed
of HDD's that have different
mirroring information. (eg. A
HDD which has been used in
the mirroring kit of another
machine is installed.)
x
Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
F
Other than cases B,
C, D, and E
x
RAID PWB trouble.
x
Both HDD’s trouble.
x
Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
x
Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.