![Sharp MD-R3 Service Manual Download Page 22](http://html.mh-extra.com/html/sharp/md-r3/md-r3_service-manual_370633022.webp)
MD-R3
– 22 –
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode (
: Zone No.)
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ H A G :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ H B G :
]
7. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button six times.
MANUAL adjustment menu
[ _ M N U _ A J S T _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode (
: Zone No.)
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 5
Press once the ENTER button.
Innermost periphery move
→
Tracking ATT (E signal) setting
[ P E G :
]
Step 6
Press once the ENTER button.
Tracking ATT (F signal) setting
[ P F G :
]
Step 7
Press once the ENTER button.
Indication of tracking EFMIO measurement (pit section)
[ P M I :
_ _ _ ]
Step 8
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A g :
]
Step 9
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B g :
]
Step 10
Press once the ENTER button.
Outside periphery move
→
Track closs setting
[ G C G :
_
]
Step 11
Press once the ENTER button.
Tracking ATT (E signal) setting
[ G E G :
]
Step 12
Press once the ENTER button.
Tracking ATT (F signal) setting
[ G F G :
]
Step 13
Press once the ENTER button.
Indication of tracking EFMIO measurement (groove section)
[ G M I :
_ _ _ ]
Step 14
Press once the ENTER button.
Focus ATT (A signal) setting
[ L A G :
]
Step 15
Press once the ENTER button.
Focus ATT (B signal) setting
[ L B G :
]
Low reflection disc
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step by step excepting the following case.
Track closs ATT setting (GTG)
→
Innermost periphery move
→
Focus ATT (B signal) setting (LBg)
Step 22
Press once the ENTER button.
Focus ATT (B signal) setting
[ S B G :
]
Step 23
Press once the ENTER button.
Offset "0" setting
→
A signal offset measurement
[ H A O :
_ _ ]
Step 24
Press once the ENTER button.
B signal offset measurement
[ H B O :
_ _ ]
Step 25
Press once the ENTER button.
E signal offset measurement
[ H E O :
_ _ ]
Step 26
Press once the ENTER button.
F signal offset measurement
[ H F O :
_ _ ]
Step 27
Press once the ENTER button.
TCRS signal offset measurement
[ T C O : _
_ _ ]
Step 28
Press once the ENTER button.
A signal offset measurement
[ L A O :
_ _ ]
Step 29
Press once the ENTER button.
B signal offset measurement
[ L B O :
_ _ ]
Step 30
Press once the ENTER button.
E signal offset measurement
[ L E O :
_ _ ]
Step 31
Press once the ENTER button.
F signal offset measurement
[ L F O :
_ _ ]
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Set value,
: Account value
• If the jog key upward/downward is pressed during setting indication, the setting increases/decreases, and the new setting is stored in RAM.
• If the REC button is pressed, the setting returns step by step excepting the following case.
A signal offset (HAO)
→
Offset tentative setting
→
RF side FG adjustment (RFG)
RF side TCRS adjustment (RCG)
→
RF side groove TG adjustment (GTG)
RF side groove TG adjustment (GTG)
→
Innermost periphery move
→
RF side pit section adjustment (PTG)
RF side pit TG adjustment (PTG)
→
RF side FG rough adjustment (RFg)
→
Laser lighting (LON)
Laser lighting (LON)
→
Offset "0" setting
→
A signal offset tentative measurement (HAo)
If the measurement value is within the OK range, " " appears on the 8th character.