![Sharp MD-R3 Service Manual Download Page 21](http://html.mh-extra.com/html/sharp/md-r3/md-r3_service-manual_370633021.webp)
– 21 –
MD-R3
Step 18
Press once the ENTER button.
Indication of measurement value
[ L B O :
_ _ _]
Step 19
Press once the ENTER button.
Indication of measurement value
[ L E O :
_ _ _]
Step 20
Press once the ENTER button.
Indication of measurement value
[ L F O :
_ _ _]
Step 21
Press once the ENTER button.
Indication of measurement value
[ T C O : _
_ _ _]
Step 22
Press once the ENTER button.
Indication of adjustment error sequence No.
[ Y O B : _
_ _ _]
Step 23
Press once the ENTER button.
Indication of adjustment status
[ D I F : _
_ _ _]
Step 24
Press once the ENTER button.
Indication of pre-adjustment not completed (00)/completed (4B)
[ A D J : _
_ _ _]
Step 25
Press once the MD STOP button. RESULT sub-menu state
[ _ R S T _ Y O B I _ ]
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Adjustment value,
: Other various informations
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button four times.
RESULT menu
[ _ R E S U L T _ _ _ ]
Step 3
Press once the MD PLAY button. Indication of set value
[ H A G : _ _ _
]
Step 4
Press once the ENTER button.
Indication of set value
[ H B G : _ _ _
]
Step 5
Press once the ENTER button.
Indication of set value
[ L A G : _ _ _
]
Step 6
Press once the ENTER button.
Indication of set value
[ L B G : _ _ _
]
Step 7
Press once the ENTER button.
Indication of set value
[ P E G : _ _ _
]
Step 8
Press once the ENTER button.
Indication of set value
[ P F G : _ _ _
]
Step 9
Press once the ENTER button.
Indication of set value
[ G E G : _ _ _
]
Step 10
Press once the ENTER button.
Indication of set value
[ G F G : _ _ _
]
Step 11
Press once the ENTER button.
Indication of set value
[ G C G : _ _ _ _
]
Step 12
Press once the MD STOP button. RESULT menu state
[ _ R E S U L T _ _ _ ]
5. RESULT mode (final adjustment)
Step No.
Setting Method
Remarks
Display
•
: Set value
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the ENTER button five times.
MANUAL auxiliary adjustment mode
[ _ M N U _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode (
: Zone No.)
[ T M P : _
_ _ _ ]
Step 4
Press once the ENTER button.
Offset "0" setting
→
A signal offset tentative measurement
[ H A o :
_ _ ]
Step 5
Press once the ENTER button.
B signal offset tentative measurement
[ H B o :
_ _ ]
Step 6
Press once the ENTER button.
E signal offset tentative measurement
[ H E o :
_ _ ]
Step 7
Press once the ENTER button.
F signal offset tentative measurement
[ H F o :
_ _ ]
Step 8
Press once the ENTER button.
Offset tentative measurement
→
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 9
Press once the ENTER button.
Innermost periphery move
→
RF side FG rough adjustment
[ R F g :
_
]
Step 10
Press once the ENTER button.
Focus ATT (A signal) tentative setting
[ S A g :
]
Step 11
Press once the ENTER button.
Focus ATT (B signal) tentative setting
[ S B g :
]
Step 12
Press once the ENTER button.
RF side pit section TG adjustment
[ P T G :
_
]
Step 13
Press once the ENTER button.
Pit section COUT level setting
[ P C H :
_
]
Step 14
Press once the ENTER button.
Outer periphery move
→
RF side groove TG adjustment
[ G T G :
_
]
Step 15
Press once the ENTER button.
Groove section COUT level setting
[ G C H :
_
]
Step 16
Press once the ENTER button.
RF side TCRS adjustment
[ R C G :
_
]
Step 17
Press once the ENTER button.
Tracking ATT (E signal) setting
[ S E G :
]
Step 18
Press once the ENTER button.
Tracking ATT (F signal) setting
[ S F G :
]
Step 19
Press once the ENTER button.
Indication of tracking EFMIO measurement
[ G M I :
_ _ _ ]
Step 20
Press once the ENTER button.
RF side pit section FG adjustment
[R F G :
_
]
Step 21
Press once the ENTER button.
Focus ATT (A signal) setting
[ S A G :
]
6. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks
Display