– 12 –
MD-MT88H/99H
DISASSEMBLY
Cares before disassembling
When assembling the machine after disassembling or
repair, observe the following requirements so as to ensure
safety and performance.
1. Remove the batteries from the machine, and take out the
mini-disc.
2. When assembling after repair, be sure to position the
wires in the same location.
Use the specified screws to fix the cabinet and the
mechanism unit. The use of the screws with length other
than specified may cause contact with the mechanism
unit resulting in malfunction.
3. When repairing, pay close attention so not to damage the
IC from static electricity.
Caution:
Carefully handle the main PWB and flexible PWB. After removing the
flexible PWB (1*) for the optical pickup from the connector, do not
touch directly the front end of flexible PWB with your hand so as to
prevent damage of optical pickup by static electricity.
(C1) x3
ø1.7 x2.5mm
(C1) x1
ø1.4 x2.5mm
(B2) x2
(C2) x1
(C3) x1
(C3) x1
(C2) x1*
Pull
Pull
Pull
Pull
Pull
Felt
Put the fold on the connector, and apply
with the felt. Sagging may result in contact
with the sheet metal.
Main PWB
Center Cabinet
(D1) x1
ø1.4 x1.5mm
(D1) x1
ø1.4 x1.5mm
Mechanism Unit
Center Cabinet
1
Bottom Cabinet
1. Screw ..................... (A1) x6
12-1
2
Top Cabinet
1. Open the Top cabinet.
12-1
2. Screw ..................... (B1) x4
3. Flexible PWB .......... (B2) x2
12-2
3
Main PWB
1. Open the Battery Lid.
12-1
2. Screw .................... (C1) x4
12-2
3. Flexible PWB ......... (C2) x2
4. Soldering ............... (C3) x2
4
Mechanism Unit
1. Screw .................... (D1) x2
12-3
2. Raise the rear part, and
remove in the arrow direction.
REMOVAL
PROCEDURE
STEP
FIGURE
Figure 12-1
Figure 12-2
Figure 12-3
(A1) x2
ø1.4 x2mm
(A1) x2
ø1.4 x2mm
(A1) x1
ø1.4 x2mm
(B1) x2
ø1.4 x2mm
(B1) x2
ø1.4 x2mm
(A1) x1
ø1.4 x2mm
Top Cabinet
Bottom Cabinet
Battery Lid
Open Lever