4.2. White balance adjustment
Adjustment item
Adjustment conditions
Adjustment procedure
1
Adjustment
Brightness : MAX
Set the luminance meter on
the center of the screen
For the details of white balance adjustment procedure, please refer to white balance
adjustment spec for current model.
1) Confirm the set condition.
2) Connect the luminance meter CA-210.
3) Through RS-232C command, adjustment mode screen is displayed.
2
Auto Adjustment
performance
[command]
Adjustment Mode
KRSW0001
KKT10037
Setting
KYOF0001
OSDS0001
SBSL16_ _
Multi point adj. Mode
MSET0000
WBI20255
Point 2
WBI20204
MG2G****
MG2B****
MG2R****
Point 1
WBI10064
MG1G****
MG1B****
MG1R****
Write
MSET0003
Set Max.Level
MGMG****
MGMB****
MGMR****
[Adjustment Procedure]
1) Using the remote control, set the LCD TV to adjustment mode.
2) Measure Max brightness (Lmax).
3) Calculate min. brightness (Lmin)=Lmax/5000.
4) Measure Point 2 brightness (Lhigh).
5) Set the reference value R,G,B of Point 2 (R2)=3264 x (204/P2)
where P2=255 x [(Lhigh-Lmin)/(Lmax-Lmin)]1/2.2
6) Set the specified gradation for point 2, fix the most faint colour to get reference
value, adjust others 2 colour to minus adjustment for reference value of point 2.
7) Measure Point 1 brightness (Llow).
8) Set the reference value R,G,B of Point 1 (R1)=1024 x (64/P1)
where P1=255 x [(Llow-Lmin)/(Lmax-Lmin)]1/2.2
9) Set the specified gradation for point 1. Set G of point 1 to the default value [(R1 x G
value of point 2/R2), with fractions rounded] and adjust RB to the reference value of
point 1.
10)Adjusted value is writing at [command] MSET0003.
11)Set the G of point Max. to the default value (4080 x G value of point 2/R2). Set the
R,B Max. value [Gmax-G value of point 2 + (R,B value of pint 2)].
12)Shut down the AC power.
*Initial value at RGB 2 point : 3264
*Initial value at RGB 1 point : 1024
[Adjustment Value]
✩
Specification data by engineering dept is set as reference.
[Reference value for adjustment reference]
Equipment: Luminance meter [Minolta CA-210]
Ref. : For inspection, set the LCD TV as below.
AV MODE: [DYNAMIC] (Reset)
Monochrome: ON
Aging Time: Minimum 60 minutes
Level
Spec
Data
Adjustment
Spec.
Inspection
Spec.
Point 2
ref.
values
Point 1
ref.
values
204
64
x=0.272
y=0.277
x=0.272
y=0.277
r
0.0010
r
0.0045
r
0.0020
r
0.0090
Summary of Contents for LC-32M400M-BK
Page 36: ...LC 32M400M BK WH RD 6 10 MEMO ...
Page 40: ...LC 32M400M BK WH RD 8 2 MAIN Unit Chip Parts Side A ...
Page 41: ...LC 32M400M BK WH RD 8 3 MAIN Unit Side B ...
Page 43: ...LC 32M400M BK WH RD 8 5 3 TERMINAL Unit Terminal Unit ...
Page 44: ...LC 32M400M BK WH RD 8 6 Terminal Unit Chip Parts ...
Page 46: ...LC 32M400M BK WH RD 9 2 2 MAIN Unit MAIN Unit 1 11 ...
Page 47: ...LC 32M400M BK WH RD 9 3 MAIN Unit 2 11 ...
Page 48: ...LC 32M400M BK WH RD 9 4 MAIN Unit 3 11 ...
Page 49: ...LC 32M400M BK WH RD 9 5 MAIN Unit 4 11 ...
Page 50: ...LC 32M400M BK WH RD 9 6 MAIN Unit 5 11 ...
Page 51: ...LC 32M400M BK WH RD 9 7 MAIN Unit 6 11 ...
Page 52: ...LC 32M400M BK WH RD 9 8 MAIN Unit 7 11 ...
Page 53: ...LC 32M400M BK WH RD 9 9 MAIN Unit 8 11 ...
Page 54: ...LC 32M400M BK WH RD 9 10 MAIN Unit 9 11 ...
Page 55: ...LC 32M400M BK WH RD 9 11 MAIN Unit 10 11 ...
Page 56: ...LC 32M400M BK WH RD 9 12 MAIN Unit 11 11 ...
Page 57: ...LC 32M400M BK WH RD 9 13 3 IR OPC Unit ...
Page 58: ...LC 32M400M BK WH RD 9 14 4 TERMINAL Unit TERMINAL Unit 1 ...
Page 59: ...LC 32M400M BK WH RD 9 15 TERMINAL Unit 2 ...
Page 60: ...LC 32M400M BK WH RD 9 16 TERMINAL Unit 3 ...
Page 75: ...LC 32M400M BK WH RD ...