LC-32M400M-BK/WH/RD
5 – 9
3. VOLUME FIXED
4. VOLUME FIXED LEVEL
5. R/C BUTTON
6. PANEL BUTTON
7. MENU BUTTON
Selection
Selection between “Variable” and “Fixed” (loop provided)
Default
Variable
Explanation
Sound volume is fixed and made invariable.
Limit in setting
• The sound volume for the ON-timer (Wake up timer) is fixed also without display of menu. Besides, the setting is made
impossible. (Basically, the menu is not displayed.)
• The following keys become invalid:
1) Sound volume Up/Down (VOL +/-) [for both remote control and the unit]
2) Mute (MUTE)
Exception
• In the item “VOLUME” of adjustment process, the sound volume can be set freely irrespective of this setting.
Remarks
• In “Variable” setting, the sound volume had been conventionally set at 1 but this operation has been abolished (and follows
the last memory).
• The sound volume for the ON-time is not set at 1 either and the sound volume set value of the ON-timer before the hotel
mode is executed.
• Setting is valid only for the speakers of the unit. (As for the headphone, the sound volume can be set up to 60 irrespective
of the limit.)
• In line output (sound volume variable), the sound volume can be adjusted from -60 to 0 irrespective of pre-adjusted value.
• As for sound volume fixing and sound volume MAX level, the sound volume fixing has priority.
• Once the sound volume has been changed by adjustment process or headphone, it should be set back to the sound volume
preset by sound volume fixing level when the adjustment process ends or when the headphone is removed.
Selection
Adjustment from 1 to 60 (no loop)
Default
20
Explanation
The sound volume to be fixed by “Volume fixed” is determined.
Limit in setting
None
Exception
None
Remarks
Setting is valid only when “Volume fixed” is selected for “fixed”.
This must be confirmed actually by changing also the sound volume in accordance with setting.
Selection
Selection between “Respond”, “Limited” and “No respond” (loop provide)
Default
Respond
Explanation
Acceptability of keys by remote control is limited or reception of keys can be prohibited.
Limit in setting
1) In “limited” setting, only power ON/OFF, sound volume
, tuning
and BACKLIGHT (brightness sensor) are
accepted.
2) In “No respond” setting, all the keys (including the power key) are not accepted.
Exception
• Adjustment process, factory setting, inspection process and hotel only keys are valid irrespective of setting.
• All the keys can be used in adjustment process, inspection mode and hotel menu irrespective of setting.
Remarks
Selection
Selection between “Respond” and “No respond” (loop provide)
Default
Respond
Explanation
All the operations by keys (except the power key) of the unit can be invalidated.
Limit in setting
Exception
• Inspection mode and hotel menu mode can be started irrespective of setting.
• All the keys can be used in adjustment process, inspection mode and hotel menu irrespective of setting.
Remarks
Selection
Selection between “Respond” and “No respond” (loop provide)
Default
Respond
Explanation
In “No respond” setting, the menu operation by the menu key of the remote control and the menu key of the unit is invalidated.
Limit in setting
• ON-timer (Wakeup Timer) is turned OFF.
• The following keys become invalid.
Wake-up timer and clock setting keys and all of the direct change keys to menu display
Exception
• Inspection mode and hotel menu mode can be started irrespective of setting.
• All the keys can be used in adjustment process, inspection mode and hotel menu irrespective of setting.
Remarks
Summary of Contents for LC-32M400M-BK
Page 36: ...LC 32M400M BK WH RD 6 10 MEMO ...
Page 40: ...LC 32M400M BK WH RD 8 2 MAIN Unit Chip Parts Side A ...
Page 41: ...LC 32M400M BK WH RD 8 3 MAIN Unit Side B ...
Page 43: ...LC 32M400M BK WH RD 8 5 3 TERMINAL Unit Terminal Unit ...
Page 44: ...LC 32M400M BK WH RD 8 6 Terminal Unit Chip Parts ...
Page 46: ...LC 32M400M BK WH RD 9 2 2 MAIN Unit MAIN Unit 1 11 ...
Page 47: ...LC 32M400M BK WH RD 9 3 MAIN Unit 2 11 ...
Page 48: ...LC 32M400M BK WH RD 9 4 MAIN Unit 3 11 ...
Page 49: ...LC 32M400M BK WH RD 9 5 MAIN Unit 4 11 ...
Page 50: ...LC 32M400M BK WH RD 9 6 MAIN Unit 5 11 ...
Page 51: ...LC 32M400M BK WH RD 9 7 MAIN Unit 6 11 ...
Page 52: ...LC 32M400M BK WH RD 9 8 MAIN Unit 7 11 ...
Page 53: ...LC 32M400M BK WH RD 9 9 MAIN Unit 8 11 ...
Page 54: ...LC 32M400M BK WH RD 9 10 MAIN Unit 9 11 ...
Page 55: ...LC 32M400M BK WH RD 9 11 MAIN Unit 10 11 ...
Page 56: ...LC 32M400M BK WH RD 9 12 MAIN Unit 11 11 ...
Page 57: ...LC 32M400M BK WH RD 9 13 3 IR OPC Unit ...
Page 58: ...LC 32M400M BK WH RD 9 14 4 TERMINAL Unit TERMINAL Unit 1 ...
Page 59: ...LC 32M400M BK WH RD 9 15 TERMINAL Unit 2 ...
Page 60: ...LC 32M400M BK WH RD 9 16 TERMINAL Unit 3 ...
Page 75: ...LC 32M400M BK WH RD ...