LC-32LE260M
8 – 1
CHAPTER 8.
SCHEMATIC DIAGRAM
[1] DESCRIPTION OF SCHEMATIC DIA-
GRAM
1. VOLTAGE MEASUREMENT CONDITION:
1) The voltages at test points are measured on exclusive AC adaptor and the stable supply voltage of AC 110-240V. Signals are fe d by a colour bar signal
generator for servicing purpose and the above voltages are measured with a 20k ohm/V tester.
2. INDICATION OF RESISTOR & CAPACITOR:
RESISTOR
1) The unit of resistance " " is omitted.
(K=k =1000 , M=M ).
2) All resistors are ± 5%, unless otherwise noted.
(K= ± 10%, F= ± 1%, D= ± 0.5%)
3) All resistors are 1/16W, unless otherwise noted.
CAPACITOR
1) All capacitors are F, unless otherwise noted.
(P=pF= F).
2) All capacitors are 50V, unless otherwise noted.
CAUTION:
This circuit diagram is original one, therefore there may be a slight
difference from yours.
SAFETY NOTES:
1) DISCONNECT THE AC PLUG FROM THE AC OUTLET
BEFORE REPLACING PARTS.
2) SEMICONDUCTOR HEAT SINKS SHOU LD BE REGARDED AS
POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS
OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " " (
) ARE IMPORTANT
FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO
REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAIN-
TAINING THE SAFETY AND PERFORMANCE OF THE SET.
Summary of Contents for LC-32LE260M
Page 16: ...LC 32LE260M 7 2 A C B D E F G H 2 10 9 8 7 6 5 4 3 1 MAIN UNIT SIDE B ...
Page 30: ...LC 32LE260M 11 9 PACKING PARTS NOT REPLACEMENT X4 S3 S4 S2 S8 S7 X1 X5 S5 X3 X7 S6 X2 X6 S1 ...
Page 32: ...LC 32LE260M 13 10 EXPLODE VIEW ...
Page 33: ...LC 32LE260M 14 ...
Page 34: ...LC 32LE260M 15 ...
Page 35: ...LC 32LE260M 16 ...