LC-32LE250M
6 – 5
[Adjustment value]
•
Teaching set send by engineering dept is set as reference.
[Reference values for adjustment reference]
Equipment
:
Luminance meter [Minolta CA-210]
Level
Spec
Data
Adjustment
Spec.
Inspection
Spec.
Point 2
ref.
values
229
x=0.272
y=0.277
•
0.0010
•
0.0020
Point 1
ref.
values
51
x=0.272
y=0.277
•
0.0045
•
0.0090
Ref.
:
For inspection, set the LCD TV as below.
AV MODE
: [DYNAMIC] (Reset)
Aging Time
: Minimum
60
minutes
3. FACTORY SETTING
AC power is plug off after shipment setting is done.
Caution
: Do not plug on again after shipment setting is done. If do, please re-do the shipment setting. Do not off
with remote control.
Model Name
Factory Setting Key
Name
Remote Control
Code
S-System Setting
OSD Language
Setting
M-Setting
100000001010110
B/G
ENGLISH
P-Setting
100000001011110
M
ENGLISH
**Please do inspection for
A3KLED3P
using NTSC
signal.
ITEM
CONDITION
PROCEDURE
Factory setting
AC power off to exit the
factory setting.
1. Setting is done with test remote control.
2. Press the ‘Factory Setting’ key on the remote control continuously.
3. When Green background appears on screen and ‘K’ mark
disappears, setting is completed.
The followings are initialised to factory setting
1)
User setting
2)
Channel data (e.g. broadcast frequencies)
3)
Manufacturer’s option settings
4)
Password data
5)
Setting values are set based on model destination
Asia ,Near and Middle
East
PHILIPPINES
(PHILIPPINES)
Summary of Contents for LC-32LE250M
Page 9: ...LC 32LE250M 4 1 CHAPTER 4 DIMENSIONS 1 DIMENSIONS Unit mm ...
Page 27: ...LC 32LE250M 9 2 A C B D E F G H 2 10 9 8 7 6 5 4 3 1 ...
Page 28: ...LC 32LE250M 9 3 A C B D E F G H 2 10 9 8 7 6 5 4 3 1 LED A Chip LED A Symbol ...
Page 29: ...LC 32LE250M 9 4 A C B D E F G H 2 10 9 8 7 6 5 4 3 1 LED B Chip ...
Page 61: ...LC 32LE250M 9 ...
Page 62: ...LC 32LE250M 10 ...
Page 63: ...LC 32LE250M 11 ...