LC-32LE250M
6 – 3
b) Component 15K 50Hz Signal Adjustment (COMP-SD)
ITEM
CONDITION
PROCEDURE
1
Setting
[Signal]
COMP 15K 50Hz
(576i)
100% Full-field Colour
Bar
[Terminal]
COMPONENT
INPUT
3
•
Feed the COMPONENT 15K 50Hz (576i) 100% Full-field
Colour Bar signal(100% colour saturation) to
COMPONENT INPUT
3
2
Auto Adjustment
Test Mode page4
(COMP SD)
At the related page, move cursor to [COMP SD ADJ], press
ENTER.
[OK] appears when finished.
100% White
•
•
Black
c)
Component 33K 60Hz Signal Adjustment (COMP-HD)
ITEM
CONDITION
PROCEDURE
1
Setting
[Signal]
COMP 33K 60Hz
(1080i)
100% Full-field Colour
Bar
[Terminal]
COMPONENT
INPUT
3
•
Feed the COMPONENT 33K 60Hz (1080i) 100% Full-field
Colour Bar signal(100% colour saturation) to
COMPONENT INPUT
3
2
Auto Adjustment
Test Mode page 5
(COMP HD)
At the related page, move cursor to [COMP HD ADJ], press
ENTER.
[OK] appears when finished.
100% White
•
•
Black