background image

LC-20S1U-S
LC-20S1U-B

3

PRECAUTION: POUR LA
PROTECTION CONTINUE
CONTRE LES RISQUES
D'INCENDIE, REMPLACER LE
FUSIBLE PAR UN FUSIBLE DE
MEME TYPE F3701 (2.0A, 250V),
F3301 (1.25A, 250V), F6700 (1.25A,
250V), F6701 (1.25A, 250V), F6702
(1.25A, 250V), F6703 (1.25A,
250V), F6704 (1.25A, 250V).

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

AVIS POUR LA SECURITE

De nombreuses pièces, électriques et mécaniques, dans
les téléviseurs présentent des caractéristiques spéciales
relatives à la sécurité, qui ne sont souvent pas évidentes
à vue. Le degré de protection ne peut pas être
nécessairement augmentée en utilisant des pièces de
remplacement étalonnées pour haute tension,
puissance, etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel; les
pièces électriques qui présentent ces particularités sont

PRECAUTIONS A PRENDRE LORS DE LA REPARATION

Ë

Ne peut effectuer la réparation qu' un technicien spécialisé qui s'est parfaitement
accoutumé à toute vérification de sécurité et  aux conseils suivants.

identifiées par la marque " 

å

 " et hachurées dans la

liste des pièces de remplacement et les diagrammes
schématiques.
Pour assurer la protection, ces pièces doivent être
identiques à celles utilisées dans le circuit d'origine.
L'utilisation de pièces qui n'ont pas les mêmes
caractéristiques que les pièces recommandées par
l'usine, indiquées dans ce manuel, peut provoquer des
électrocutions, incendies, radiations X ou autres
accidents.

AVERTISSEMENT

1. N'entreprendre aucune modification de tout circuit.

C'est dangereux.

2. Débrancher le récepteur avant toute réparation.

VERIFICATIONS CONTRE L'INCEN-DIE ET
LE CHOC ELECTRIQUE

Avant de rendre le récepteur à l'utilisateur, effectuer
les vérifications suivantes.
1. Inspecter tous les faisceaux de câbles pour s'assurer

que les fils ne soient pas pincés ou qu'un outil ne soit
pas placé entre le châssis et les autres pièces
métalliques du récepteur.

2. Inspecter tous les dispositifs de protection comme les

boutons de commande non-métalliques, les isolants,
le dos du coffret, les couvercles ou blindages de réglage
et de compartiment, les réseaux de résistance-capacité,
les isolateurs mécaniques, etc.

3. S'assurer qu'il n'y ait pas de danger d'électrocution en

vérifiant la fuite de courant, de la facon suivante:

Brancher le cordon d'alimentation directem-ent à une
prise de courant de 110-240V. (Ne pas utiliser de
transformateur d'isolation pour cet essai).

A l'aide de deux fils à pinces, brancher une résistance
de 1.5k

 10 watts en parallèle avec un condensateur

de 0.15µF en série avec toutes les pièces métalliques
exposées du coffret et une terre connue comme une

conduite électrique ou une prise de terre branchée à la
terre.

Utiliser un voltmètre CA d'une sensibilité d'au moins
5000

/V pour mesurer la chute de tension en travers

de la résistance.

Toucher avec la sonde d'essai les pièces métalliques
exposées qui présentent une voie de retour au châssis
(antenne, coffret métallique, tête des vis, arbres de
commande et des boutons, écusson, etc.) et mesurer
la chute de tension CA en-travers de la résistance.
Toutes les vérifications doivent être refaites après avoir
inversé la fiche du cordon d'alimentation. (Si nécessaire,
une prise d'adpatation non polarisée peut être utilisée
dans le but de terminer ces vérifications.)
Tous les courants mesurés ne doivent pas dépasser
0.5 mA.
Dans le cas contraire, il y a une possibilité de choc
électrique qui doit être supprimée avant de rendre le
récepteur au client.

A     V

DVM

ECHELLE CA

1.5k ohm

10W

AUX PIECES
METALLIQUES
EXPOSEES

BRANCHER A UNE
TERRE CONNUE

0.15 

µ

F

SONDE D'ESSAI

Summary of Contents for LC-20S1UB

Page 1: ...ublished to be used for after sales service only The contents are subject to change without notice LCD COLOR TELEVISION CONTENTS IMPORTANT SERVICE SAFETY PRECAUTION 2 SPECIFICATIONS 5 OPERATION MANUAL 6 DIMENSIONS 9 REPLACEMENT PARTS LIST 10 PACKING OF THE SET 13 Page OUTLINE The above model is based on the LC 20S2U S Its desktop stand has been redesigned This Service Manual covers the modificatio...

Page 2: ...ty characteristics as the factory recommended replacement parts shown in this service manual may create shock fire or other hazards WARNING 1 For continued safety no modification of any circuit should be attempted 2 Disconnect AC power before servicing BEFORE RETURNING THE RECEIVER Fire Shock Hazard Before returning the receiver to the user perform the following safety checks 1 Inspect all lead dr...

Page 3: ...nuel peut provoquer des électrocutions incendies radiations X ou autres accidents AVERTISSEMENT 1 N entreprendre aucune modification de tout circuit C est dangereux 2 Débrancher le récepteur avant toute réparation VERIFICATIONS CONTRE L INCEN DIE ET LE CHOC ELECTRIQUE Avant de rendre le récepteur à l utilisateur effectuer les vérifications suivantes 1 Inspecter tous les faisceaux de câbles pour s ...

Page 4: ... which is higher than the conventional lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However Since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder co...

Page 5: ...e English French Spanish Power supply DC 12 V AC 110 240 V 50 60 Hz AC Adapter AC 125V MAX AC Cord Power consumption Weight Accessories Remote control Battery x2 Antenna cable AC adapter AC cord Cable clamp Operation manual Model LC 20S1U 19 7 Advanced Super View BLACK TFT LCD 3D Y C FILTER 14 1 lbs 6 4 kg w o accessories 4 7 cm 2 pcs As a part of policy of continuous improvement SHARP reserves th...

Page 6: ...he screen to the best viewable angle OPC sensor Remote control sensor OPC indicator Optical Picture Control The Optical Picture Control indicator lights up green when the BRIGHTNESS is set to AUTO POWER indicator A green indicator lights when the power is on and a red indicator lights when in the standby mode the indicator will not light when the main power is off Adjustable range S VIDEO INPUT ON...

Page 7: ...ENU Display the menu screen 14 CC Display Closed Caption subtitles 15 TV VIDEO Select a Liquid Crystal Television input source 16 FLASHBACK Return to the previous channel 17 Channel Select Set the channel 1 10 2 3 5 6 7 8 9 11 12 14 15 16 17 4 13 PREPARATION Batteries for the Remote Control Before using the LCD TV set for the first time install two AAA size batteries supplied When the batteries be...

Page 8: ...al If your external device has a component terminal COMPONENT connection is recom mended you can view high quality pictures Example DVD Player etc Playback from 480 progressive output for DVD and DTV is available Example VCR Laser disc player If your external device has an S video terminal S VIDEO connection is recom mended To COMPONENT terminal Connecting a VCR DVD player or a video camera AV IN1...

Page 9: ... 8 403 3 47 32 107 243 64 68 119 64 283 35 939 64 244 10 23 64 263 619 64 160 16 3 16 411 9 228 5 3 16 5 315 16 100 3 15 16 100 1 27 32 47 11 27 32 300 8 5 17 64 134 7 51 64 198 14 1 64 356 649 64 172 12 69 64 156 13 7 32 336 15 29 32 404 Unit inch mm ...

Page 10: ...AG 1 3 VSP7040PB608S J Speaker x2 AN 1 4 XEBSN40P10000 J Screw x8 AB 2 CCABBA262WJ04 X Cabiet B Ass y BD 2 1 Not Available Cabinet B 2 2 GCOVAA500WJKA J Terminal Cover AM 2 3 GLEGGA026WJSA J Leg x2 AF 2 4 JBTN A181WJKA J Operation Button AL 2 5 JBTN A184WJKA J Power Button AG 2 6 LANGF2155CEFW J Round Lock AD 2 7 MSPRCA014WJFW J Power Button Spring AB 2 8 PSPAHA279WJZZ J Spacer x1 AC 2 9 TLABZA447...

Page 11: ... 3 1 1 3 1 1 5 1 1 2 1 1 6 1 3 5 3 3 5 3 6 5 3 7 5 3 1 5 3 2 5 3 4 5 3 5 5 3 8 5 3 4 26 5 4 1 1 1 1 1 1 1 8 1 1 7 1 5 1 3 1 4 1 4 1 2 R C LED PWB 5 10 5 14 5 12 5 11 5 13 5 13 5 1 5 7 5 8 5 9 5 6 19 25 18 15 9 16 11 14 9 1 9 2 2 21 27 2 3 2 8 2 9 2 6 2 1 2 3 24 17 7 8 23 2 10 2 11 2 4 2 5 2 7 12 20 22 2 2 6 5 3 R Inverter PWB Sub PWB Main PWB Q 5 5 5 2 5 2 5 2 5 2 5 2 5 2 1 5 2 1 5 2 1 5 2 1 5 2 1...

Page 12: ...JZZ X Operation Manual AT LC 20S1U S TiNS A857WJN1 X Operation Manual LC 20S1U B å UADP A044WJPZ J AC Adapter BC SPAKCA858WJZZ Packing Case LC 20S1U S SPAKCA859WJZZ Packing Case LC 20S1U B SPAKFA310WJZZ Buffer Material Accessories SPAKFA547WJZZ Packing Material R C SPAKPA188WJZZ Wrapping Paper SPAKXA336WJZZ Buffer Material SSAKA0101GJZZ Polyethylene Bag TLABKA009WJZZ Carton Label SERVICE JIGS USE ...

Page 13: ...FA547WJZZ Carton Label TLABKA009WJZZ Infrared R C Unit RRMCGA174WJSA LC 20S1U S RRMCGA174WJSB LC 20S1U B AC Adapter UADP A044WJPZ AC Cord QACCDA023WJPA Antenna Cable QCNWG0003CEPA R L Operation Manual TiNS A857WJZZ LC 20S1U S TiNS A857WJN1 LC 20S1U B Cable Clamp 1pc LHLDWA002WJSB Questionnaire Card TCADEA028WJZZ LC 20S1U S TCADEA126WJZZ LC 20S1U B AAA size Battery 2pcs Polyethylene Bag SSAKA0101GJ...

Page 14: ...or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group Quality Reliability Control Center Yaita Tochigi 329 2193 Japan TQ1743 S Apr 2004 Printed in Japan MI KG Design and Production Information Design Japan Production SEMEX ...

Reviews: