background image

LC-15S1U-S
LC-15S1U-B

3

PRECAUTION: POUR LA
PROTECTION CONTINUE
CONTRE LES RISQUES
D'INCENDIE, REMPLACER LE
FUSIBLE PAR UN FUSIBLE DE
MEME TYPE F3701 (2.0A, 250V),
F3301 (1.25A, 250V), F6501 (1.25A,
250V), F6502 (1.25A, 250V).

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

AVIS POUR LA SECURITE

De nombreuses pièces, électriques et mécaniques, dans
les téléviseurs présentent des caractéristiques spéciales
relatives à la sécurité, qui ne sont souvent pas évidentes
à vue. Le degré de protection ne peut pas être
nécessairement augmentée en utilisant des pièces de
remplacement étalonnées pour haute tension,
puissance, etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel; les
pièces électriques qui présentent ces particularités sont

PRECAUTIONS A PRENDRE LORS DE LA REPARATION

Ë

Ne peut effectuer la réparation qu' un technicien spécialisé qui s'est parfaitement
accoutumé à toute vérification de sécurité et  aux conseils suivants.

identifiées par la marque " 

å

 " et hachurées dans la

liste des pièces de remplacement et les diagrammes
schématiques.
Pour assurer la protection, ces pièces doivent être
identiques à celles utilisées dans le circuit d'origine.
L'utilisation de pièces qui n'ont pas les mêmes
caractéristiques que les pièces recommandées par
l'usine, indiquées dans ce manuel, peut provoquer des
électrocutions, incendies, radiations X ou autres
accidents.

AVERTISSEMENT

1. N'entreprendre aucune modification de tout circuit.

C'est dangereux.

2. Débrancher le récepteur avant toute réparation.

VERIFICATIONS CONTRE L'INCEN-DIE ET
LE CHOC ELECTRIQUE

Avant de rendre le récepteur à l'utilisateur, effectuer
les vérifications suivantes.
1. Inspecter tous les faisceaux de câbles pour s'assurer

que les fils ne soient pas pincés ou qu'un outil ne soit
pas placé entre le châssis et les autres pièces
métalliques du récepteur.

2. Inspecter tous les dispositifs de protection comme les

boutons de commande non-métalliques, les isolants,
le dos du coffret, les couvercles ou blindages de réglage
et de compartiment, les réseaux de résistance-capacité,
les isolateurs mécaniques, etc.

3. S'assurer qu'il n'y ait pas de danger d'électrocution en

vérifiant la fuite de courant, de la facon suivante:

Brancher le cordon d'alimentation directem-ent à une
prise de courant de 110-240V. (Ne pas utiliser de
transformateur d'isolation pour cet essai).

A l'aide de deux fils à pinces, brancher une résistance
de 1.5k

 10 watts en parallèle avec un condensateur

de 0.15µF en série avec toutes les pièces métalliques
exposées du coffret et une terre connue comme une

conduite électrique ou une prise de terre branchée à la
terre.

Utiliser un voltmètre CA d'une sensibilité d'au moins
5000

/V pour mesurer la chute de tension en travers

de la résistance.

Toucher avec la sonde d'essai les pièces métalliques
exposées qui présentent une voie de retour au châssis
(antenne, coffret métallique, tête des vis, arbres de
commande et des boutons, écusson, etc.) et mesurer
la chute de tension CA en-travers de la résistance.
Toutes les vérifications doivent être refaites après avoir
inversé la fiche du cordon d'alimentation. (Si nécessaire,
une prise d'adpatation non polarisée peut être utilisée
dans le but de terminer ces vérifications.)
Tous les courants mesurés ne doivent pas dépasser
0.5 mA.
Dans le cas contraire, il y a une possibilité de choc
électrique qui doit être supprimée avant de rendre le
récepteur au client.

A     V

DVM

ECHELLE CA

1.5k ohm

10W

AUX PIECES
METALLIQUES
EXPOSEES

BRANCHER A UNE
TERRE CONNUE

0.15 

µ

F

SONDE D'ESSAI

Summary of Contents for LC-15S1UB

Page 1: ...ublished to be used for after sales service only The contents are subject to change without notice LCD COLOR TELEVISION CONTENTS IMPORTANT SERVICE SAFETY PRECAUTION 2 SPECIFICATIONS 5 OPERATION MANUAL 6 DIMENSIONS 9 REPLACEMENT PARTS LIST 10 PACKING OF THE SET 13 Page OUTLINE The above model is based on the LC 15S2U S Its desktop stand has been redesigned This Service Manual covers the modificatio...

Page 2: ...factory recommended replacement parts shown in this service manual may create shock fire or other hazards WARNING 1 For continued safety no modification of any circuit should be attempted 2 Disconnect AC power before servicing BEFORE RETURNING THE RECEIVER Fire Shock Hazard Before returning the receiver to the user perform the following safety checks 1 Inspect all lead dress to make certain that l...

Page 3: ...ectrocutions incendies radiations X ou autres accidents AVERTISSEMENT 1 N entreprendre aucune modification de tout circuit C est dangereux 2 Débrancher le récepteur avant toute réparation VERIFICATIONS CONTRE L INCEN DIE ET LE CHOC ELECTRIQUE Avant de rendre le récepteur à l utilisateur effectuer les vérifications suivantes 1 Inspecter tous les faisceaux de câbles pour s assurer que les fils ne so...

Page 4: ... which is higher than the conventional lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However Since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder co...

Page 5: ...language English French Spanish Power supply DC 12 V AC 110 240 V 50 60 Hz AC Adapter AC 125V MAX AC Cord Power consumption Weight Accessories Remote control Battery x2 Antenna cable AC adapter AC cord Cable clamp Operation manual LC 15S1U Model As a part of policy of continuous improvement SHARP reserves the right to make design and specification changes for product improvement without prior noti...

Page 6: ...he screen to the best viewable angle OPC sensor Remote control sensor OPC indicator Optical Picture Control The Optical Picture Control indicator lights up green when the BRIGHTNESS is set to AUTO POWER indicator A green indicator lights when the power is on and a red indicator lights when in the standby mode the indicator will not light when the main power is off Adjustable range S VIDEO INPUT ON...

Page 7: ...ENU Display the menu screen 14 CC Display Closed Caption subtitles 15 TV VIDEO Select a Liquid Crystal Television input source 16 FLASHBACK Return to the previous channel 17 Channel Select Set the channel 1 10 2 3 5 6 7 8 9 11 12 14 15 16 17 4 13 PREPARATION Batteries for the Remote Control Before using the LCD TV set for the first time install two AAA size batteries supplied When the batteries be...

Page 8: ...al If your external device has a component terminal COMPONENT connection is recom mended you can view high quality pictures Example DVD Player etc Playback from 480 progressive output for DVD and DTV is available Example VCR Laser disc player If your external device has an S video terminal S VIDEO connection is recom mended To COMPONENT terminal Connecting a VCR DVD player or a video camera AV IN1...

Page 9: ...m 1419 64 363 125 64 307 12 3 4 324 6 15 16 176 2 9 3 32 231 17 64 7 951 64 249 35 71 8 181 9 1 64 229 11 7 32 285 61 64 153 12 55 64 129 11 1 2 292 12 35 64 319 355 64 98 515 64 133 221 64 59 5 3 16 132 6 1 4 159 315 16 100 3 15 16 100 1 13 16 46 ...

Page 10: ...35WJZZ X Energy Star Label 1 1 8 QEARZ0047CEZZ J Grounding Part AC 1 2 QCNW B662WJQZ J Connecting Cord SP AH 1 3 VSP7530PB628B J Speaker x2 AN 1 4 XEBSN30P08000 J Screw x6 AA 2 CCABBA266WJ06 X Cabinet B Ass y BC 2 1 Not Available Cabinet B 2 2 GLEGGA027WJSA J Rubber Leg x2 AF 2 3 JBTN A182WJKA J Operation Button AK 2 4 JBTN A185WJKA J Power Button AF 2 5 LANGF2155CEFW J Round Lock AD 2 6 LANGTA079...

Page 11: ...3 3 3 1 3 2 3 1 3 3 1 2 3 1 1 1 1 1 1 1 7 1 1 6 1 1 8 1 1 4 1 1 4 1 1 2 1 1 5 1 1 3 1 1 3 1 3 1 1 1 3 1 2 1 4 1 4 4 6 4 5 4 4 4 3 2 3 2 1 2 4 2 7 4 9 4 8 4 7 2 6 2 2 2 2 2 10 4 1 17 13 14 18 12 7 2 8 11 9 4 1 4 11 4 14 4 10 4 12 2 10 2 11 4 16 4 18 4 17 4 15 4 5 4 2 4 13 4 6 4 2 1 4 2 2 19 R C LED PWB Sub PWB Main PWB 2 5 6 5 15 16 20 2 8 10 2 9 2 12 ...

Page 12: ...26WJZZ X Questionnaire Card LC 15S1U B TiNS A857WJZZ X Operation Manual AT LC 15S1U S TiNS A857WJN1 X Operation Manual LC 15S1U B å UADP A044WJPZ J AC Adapter BC SPAKCB273WJZZ Packing Case LC 15S1U S SPAKCB523WJZZ Packing Case LC 15S1U B SPAKFA373WJZZ Packing Material Accessories SPAKPA081WJZZ Wrapping Paper SPAKXA296WJZZ Buffer Material SSAKA0101GJZZ Polyethylene Bag TLABKA009WJZZ Carton Label SE...

Page 13: ...1pc LHLDWA002WJSB AAA size Battery 2pcs Packing Material Accessories SPAKFA373WJZZ AC Adapter UADP A044WJPZ AC Cord QACCDA023WJPA Wrapping Paper SPAKPA081WJZZ Buffer Material SPAKXA296WJZZ Buffer Material SPAKXA296WJZZ Infrared R C Unit RRMCGA174WJSA LC 15S1U S RRMCGA174WJSB LC 15S1U B Antenna Cable QCNWG0003CEPA Packing Case SPAKCB273WJZZ LC 15S1U S SPAKCB523WJZZ LC 15S1U B Carton Label TLABKA009...

Page 14: ...or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group Quality Reliability Control Center Yaita Tochigi 329 2193 Japan TQ1744 S Apr 2004 Printed in Japan MI KG Design and Production Information Design Japan Production SEMEX ...

Reviews: