EN - 8
Electrical connection for your
hob
• . Before proceeding with the electri
-
cal connection, verify that the current
carrying capacity of the system and
the socket is adequate for the maxi-
mum power rating of the hob.
•
· Electrical installation of the residen-
ce and the electrical current plug in
use must be grounded and must con-
form with safety regulations.
•
· If there is no dedicated hob circuit
and fused switch, they must be ins-
talled by a qualified electrician before
the hob is connected.
•
The fused switch must be easily ac-
cessible once the hob has been ins-
talled.
•
· Do not use adaptors, multiple soc-
kets and/or extension leads.
•
· A circuit breaker with a contact ope-
ning of at least 3 mm, rated 20 A and
delayed functioning type must be ins-
talled inside the supply circuit.
•
For the touch controlled vitroceramic
hob, the cable must be H05VV-F
3X
2
,5 mm² / 60227 IEC 53. You will
find the connection diagram shown on
the back of your appliance.
•
During installation, please insure that
isolated cables are used. An incorrect
connection might damage your app-
liance. The warranty will not cover
such damages.
•
All repairs must be carried out by an
authorized service technician or a
qualified electrician.
•
·Unplug your appliance before each
maintenance. For reconnection,
follow the connection diagrams
carefully.
The supply cable connection can differ
according to the terminal box type.
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
3x2,5 mm² 220V~
3x2,5 mm² 230V~
3x2,5 mm² 240V~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
5x1.5 mm² 380V 3N~
5x1.5 mm² 400V 3N~
5x1.5 mm² 415V 3N~
/