E-7
PREPARATION
1
2
3
4
Remove the Back Panel.
Remove the plastic bag
from the each filter.
Install the filters in the correct order as
shown.
Install the Back Panel.
OPERATION
START
STOP
The fan speed is automatically controlled depending on the
5 detection. (PM2.5 / Usual dust / Temperature /Humidity /
Light)
The unit releases Plasmacluster ions with strong airflow
and collects dusts while decreasing static electricity for
10 minutes. After that, the DUST sensor sensitivity is
automatically set to ”HIGH”and quickly detects impurities
and clean the air powerfully for 50 minutes.
• When the operation finishes after
60 minutes, the unit will return
to the prior operation mode. It is
able to change the other mode
during this mode.
• The Plasmacluster Ion can not
be turned “OFF”. (Ref.E-10)
NOTE
2
1
3
3
Back Panel
HEPA Filter
Deodorizing Filter
The fan speed is automatically controlled depending on the 7
detection. (Ref.E-1)
Click
Deodorizing Filter
HEPA Filter
Tag
•
Front Display, Cleanliness Monitor and Air Outlet LED
automatically switch ON and OFF based on room
brightness. (When light control is set to "Auto". Ref.E-11)
NOTE
NOTE
• When replacing the filter, making a memo of the start of
use date is recommended.
START/STOP
CLEAN ION SHOWER MODE
AUTO MODE
(KC-G41R)
INTELLIGENT MODE
(KC-G61R / KC-G51R)
FILTER INSTALLATION
Always be sure to remove the
power plug from the wall outlet.
ENG
LI
SH
E-8
1
2
3
4
Remove
the Water Tank.
Fill the Water Tank
with the tap water.
Install
the Water Tank.
ON
OFF
Use this mode when you want to remove adhering odor,
germs, and other substances from cloths, sofas and curtains.
NOTE
Temperature
Humidity
ALL MODE
(Except MAX / MED / LOW /
SLEEP)
SLEEP
MODE
~18 ºC
65 %
65 %
18 ºC~24 ºC
60 %
65 %
24 ºC
~
55 %
60 %
SLEEP
POLLEN
MAX
MED
LOW
SLEEP
The unit will operate quietly, and the fan speed is
automatically switched depending on the amount of impurities
in the air.
The Front Display, Cleanliness Monitor and Air Outlet LED
go off automatically.
(When light control is set to "Auto". Ref.E-11)
POLLEN
The DUST SENSOR sensitivity is automatically set to “HIGH”
and quickly detects impurities such as dust and pollen and
clean the air powerfully.
NOTE
ON
CANCELLATION
Operation of the operation panel will be locked.
2
1
2
1
Click
To prevent leaks ,
securely tighten the
Tank Cap.
more
3 sec.
• Emits highdensity Plasmacluster Ions only in the forward
direction.
• Discharges stronger air for 8 hours. When the operation
finishes, the unit will return to its prior operation mode.
• The Plasmacluster Ion can not be turned “OFF”. (Ref.E-10)
NOTE
PLASMACLUSTER ION
SPOT MODE
SELECTING MODE
CHILD LOCK
HUMIDIFICATION SETTING
more
3 sec.
When operating with Humidification ON in the modes in
the table below, the unit automatically controls humidity by
sensing temperature and humidity.
(Except MAX / MED /
LOW mode.)
REFILLING THE WATER TANK
Adjust Front Louver manually.