6
ANTI-TIP
NORMAL INSTALLATION STEPS
ANTI-TIP BRACKET INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY WARNING
To reduce the risk of tipping of the range, the range must be secured
to the floor by properly installed Anti-Tip bracket and screws packed
with the range. Failure to install the Anti-Tip bracket will allow the
range to tip over if excessive weight is placed on an open door or if
a child climbs upon it. Serious injury might result from spilled hot
liquids or from the range itself.
If range is ever moved to a different location, the Anti-Tip bracket
must also be moved and installed with the range. Instructions are
provided for installation in wood or cement fastened to either the floor
or wall. When installed to the wall, make sure that screws completely
penetrate dry wall and are secured in wood or metal. When fastening
to the floor or wall, be sure that screws do not penetrate electrical
wiring or plumbing.
1
LOCATE THE BRACKET - USING THE TEMPLATE
The bracket may be located on either the left or right side of the
range. Use the information below to locate the bracket if template
is not available.
Mark the floor or wall where left or right side of the range will be
located. If rear of range is against the wall or no further than 1 1/4-
inches from wall when installed, you may use the wall or floor mount
method. If molding is installed and does not allow the bracket to fit
flush against the wall, remove molding or mount bracket to the floor.
For wall mount, locate the bracket by placing the back edge of the
template against the rear wall and the side edge of template on the
mark made referencing the side of the range. Place bracket on top
of template and mark location of the screw holes in wall. If rear of
range is further than 1 1/4-inches from the wall when installed, attach
bracket to the floor. For floor mount, locate the bracket by placing
back edge of the template where the rear of the range will be located.
Mark the location of the screw holes, shown in template.
terminal
block
ground
screw
ground
screw
ground
wire lead
ground plate
ground
plate
ground strap
line 2
neutral
line 1
proper ground for
4-wire permanent
connection
Figure 11
FOR 3 & 4-WIRE PERMANENT CONNECTIONS
terminal
block
ground
screw
ground
screw
ground
wire lead
ground plate
ground
plate
ground strap
line 2
neutral
line 1
proper ground for
4-wire permanent
connection
Figure 12
4-WIRE PERMANENT CONNECTION ONLY
INSTALLATION MANUAL
Figure 13
Ground strap
terminal block
Note:
Install strain relief
clamp. Center must
always be attached to the
center terminal on block.
Connect neutral here.
Connect line
1 here.
Connect
line 2
here.
A user supplied strain relief
clamp must be installed at
this location. It requires
1
3
/
8
-inches (3.5 cm)
diameter cord kit hole.
3-WIRE CONNECTION
Figure 10