background image

ENGLISH

E-3

CAUTIONS CONCERNING OPERATION

•  Do not block the air intake and/or outlet.

•  Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into 

contact with steam.

•  Do not lay the unit down when turned on. 

•  Always hold the handle on both sides of the unit when moving it.

 

Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting 

in personal injury.

•  Do not operate the unit without the filter. 

•  Do not wash and reuse the filter . 

 

Not only does it not improve filter performance, but also may cause electrical shock or malfunction.

•  Clean the exterior with a soft cloth only.

 

Otherwise the unit surface may get damaged or cracked.

 

In addition, the sensors may malfunction as a result.

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION GUIDELINES

•  During operation, please place the unit at least 2 m away from equipment utilizing electrical 

waves such as televisions, radios or wave clocks.

•  Avoid locations where curtains, etc., come into contact with the air intake or outlet.

  Curtains, etc., may become dirty or a until malfunction may occur.

•  Avoid  locations  where  the  unit  is  exposed  to  condensation, due  to  rapid  temperature 

changes.

 

(If it is unavoidable please allow unit to stand for 1 hour before switching on.)

  (Use under appropriate conditions between 0 and 35˚C in the room.)

•  Place on a stable surface with sufficient air circulation.

  

  When placing the unit on a thick carpeted area, it may cause the unit to vibrate slightly.

•  Do not install when there is a possibility of soot, such as in a kitchen, etc.

  The unit surface may crack as a result.

•  Leave about  60cm of space from the wall.

  The wall behind the air outlet may become dirty as time passes. When using the unit for an ex-

tended period of time  in the same location, use a vinyl sheet, etc., to prevent the wall from becom-

ing dirty. In addition, periodically clean the wall.

FILTER GUIDELINES

•  Follow the instructions in this manual for correct care and maintenance of the filter.

  Use only filter designed for this product.

FU-Y30J-W.indd   5

09.10.9   9:20:26 AM

Summary of Contents for FU-Y30J-W

Page 1: ...ENGLISH R Plasmacluster is a trademark of Sharp Corporation Free standing type AIR PURIFIER OPERATION MANUAL FU Y30J W ...

Page 2: ...purchasing the optional replacement filter NOTE The air purifier is designed to remove air suspended dust and odour but not harmful gases for example carbon monoxide contained in cigarette smoke If the odour sources still exist it cannot completely remove the odour for example odours from construction materials and pet odours It is suggested to open the window a bit when you are smoking in order t...

Page 3: ...RP CORPORATION for breaking down and inactivating such potential allergens as the faecal matter or corpses of aerial mites 1 viruses 2 and mould and bacteria 3 suspended in the air and has been substantiated by third party organisa tions both in Japan and overseas When there is a high density of Plas macluster ions in the air the smell of cigarette smoke trapped in curtains or sofas is removed in ...

Page 4: ...erate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity conditions such as a bathroom Be cautious when cleaning the unit Corrosive cleansers may damage the exterior Only Sharp Approved Service Centres should service this air purifier Contact your nearest Ap proved Service Centre for any prob...

Page 5: ...s televisions radios or wave clocks Avoid locations where curtains etc come into contact with the air intake or outlet Curtains etc may become dirty or a until malfunction may occur Avoid locations where the unit is exposed to condensation due to rapid temperature changes If it is unavoidable please allow unit to stand for 1 hour before switching on Use under appropriate conditions between 0 and 3...

Page 6: ...Handle Main Unit E 4 MAIN UNIT DISPLAY ILLUSTRATIVE DIAGRAM PART NAMES POWER ON OFF Button Plasmacluster Ion ON OFF Button MODE Button Fan Speed Indicator Lights Plasmacluster Ion ON OFF Indicator Light ...

Page 7: ...ENGLISH E 5 INCLUDED Operation manual BACK Shape of plug depends on country Handle Filter Date Label Back Panel Tab Air Outlet Power Cord Plug Air Inlet Dust Collection Deodorising Filter ...

Page 8: ...tic bag Be sure to remove the filter from the plastic bag before using the unit Remove the filter Remove the Back Panel Pull the tab at the top of the Back Panel Intall the filter FILTER INSTALLATION Remove the Filter from the plastic bag Do not install the filter backwards or the unit will not operate properly Place the Filter within the main unit 1 2 2 1 1 Tab ...

Page 9: ...GLISH Replace the Back Panel to the main unit E 7 2 3 Push until it clicks into place Fill in the usage start date on the Date Label Date Label Use the date as a guide for the filter replacement schedule ...

Page 10: ...evious mode it was operated in MODE Button Plasmacluster Ion ON OFF Button Press the MODE Button to select the desired fan speed Indicator Lights will show the fan speed currently select ed The operation mode can be switched as below Press the Plasmacluster Ion ON OFF Button to turn Plasmacluster Ion Mode ON and OFF When Plasmacluster is ON the Plasmacluster Indica tor Light will turn on blue LOW ...

Page 11: ...oak the back panel in water with kitchen detergent for approx 10min Avoid scrubbing the back panel hard when washing Rinse the back panel repeatedly with clean water to remove the solution residue Drip dry filter to remove excess water UNIT Care Cycle Whenever dust accumulates on the unit or every 1 month To prevent dirt or stains on the main unit clean as often as necessary If stains are allowed ...

Page 12: ...ore frequently if the product is used in a condition sig nificantly severer than normal household use FILTER REPLACEMENT GUIDELINES Dust Collection Deodorising Filter Filter About 2 years after opening REPLACING THE FILTER 1 See page E 6 7 for directions on how to install the filter when re placing 2 Fill in the usage start date of the filter on the Date Label Replacement Filters Model FZ Y30SFJ D...

Page 13: ...king sounds may be audible when the unit is gen erating ions The discharged air has an odour Check to see if the filter are heavily soiled Replace the filter Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour These ozone emissions are well below safety levels TROUBLESHOOTING If you still require service contact your SHARP approved service centre SHARP approved servic...

Page 14: ...ed It indicates the space where a certain amount of dust particles can be removed in 30 minutes JEM1467 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room at a height of approximately 1 2 meters from the floor when the product is placed next to a wall and run at the MAX operation position Standby Power In order to operate the electrical c...

Page 15: ...ENGLISH Memo ...

Page 16: ...hina 09K 1 SHARP CORPORATION OF AUSTRALIA PTY LTD A B N 40 003 039 405 1 HUNTINGWOOD DRIVE HUNTINGWOOD N S W 2148 P O BOX 6827 BLACKTOWN N S W 2148 SHARP CORPORATION OF NEW ZEALAND LIMITED 59 HUGO JOHNSTON DRIVE PENROSE AUCKLAND ...

Reviews: