FO-DC500U
FO-DC600U
FO-LN1
FO-NP1
Manufactured in or before Aug.
Manufactured in or after Sep.
Manufactured in or before Aug.
Manufactured in or after Sep.
FO-DC500: TA69D or earlier
O
X(*1)
O
∆
(*3)
FO-DC600: TA70C or earlier
FO-DC500: TA69F or later
X(*2)
O
∆
(*3)
O
FO-DC600: TA70E or later
– 1 –
1. Specification changes
3. After upgrading FLASH ROM
After upgrading from version TA69D or earlier to TA69F (Sep. version) or later on FO-DC500, or after upgrading from version TA70C or earlier to TA70E
(Sep. version) or later on FO-DC600, perform the following to activate the functions 1, 2, 3, 5, 6 and 7 in “Specification changes”.
Go through MENU
→
9
→
→
8
→
#
→
7
→
START to enter the diag mode. Then holding down Z key, select “Upgrade Setting” and press START
to perform upgrade.
* After this operation, the bit is set to “1” for soft switches SW60 No.1-No.4, SW66 No.7 and SW68 No.3.
* When there is no data to save, clear the memory after upgrading. Settings return to the default and the specification changes above become effective.
No.
Description
Purpose
Corresponding page in service manual
FO-DC500U
FO-DC600U
1
REPORT key operations modified
Functionality improvement 1-3
1-3
2
Max. scan length changed: 19 to 38 inches
Functionality improvement 1-1, 1-4, 2-21
1-1, 2-21
3
Display thumbnails of attachments to Transaction Report
Functionality improvement 2-21
2-21
4
Line monitor added
Functionality improvement 2-14
2-14
5
Fax Transfer function added
Functionality improvement 2-20
2-20
6
PC FAX function added
Functionality improvement 2-20
2-20
7
Multicast transmission function added
Functionality improvement 2-20
2-20
8
Insertion of separate page when network printing
Functionality improvement 2-21, 2-23, 2-32, 2-33 2-21, 2-23, 2-32, 2-33
9
Activation switch added for activating new functions
Service
2-2, 2-6
2-2, 2-6
2. Soft switch changes
SW9
8
Action when RTN received
Handle to no error
Handle to error
0
Change
SW22
4
Line monitor up to Phase A
On
Off
0
Addition
5
Monitoring dial signal up to Phase A
Monitoring fax signal and dial signal Monitoring fax signal only
0
Addition
1
Reserved
1
Change
SW60
2
Reserved
1
Change
3
Reserved
1
Change
4
Reserved
1
Change
SW66
7
Maximum size of input document
38 inch
19 inch
1
Addition
SW68
3
Image length of TX transaction report
Reduce image of whole 1st page
15 cm image from top of 1st page
1
Addition
SW78
4
Criterion of resolution when receiving
Millimeter
Not specified
0
Addition
SW86
6
Transferred fax image
Printed at transferred error only
Printed every time
0
Addition
7
Insertion of Adobe’s URL into E-mail
No
Yes
0
Addition
SW90
1
Method of detecting CI frequency
Firmware
Modem
0
Addition
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Remarks
Initial
setting
1
0
4. Connection between network option and FLASH ROM version
(*1) : Existing functions are supported and none of new functions are.
(*2) : PC FAX cannot be used (additional software will be made available on the Web by U.S.A.)