16
R-1210
R-1211
25
P41
OUT
Terminal not used.
26
P40
IN
Connected to GND through the pull-down resistor R100.
27
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied.
28-29
P71-P70
OUT
Terminal not used.
30
XIN
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to XOUT terminal.
31
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
32
VSS
IN
Power source voltage: -5.0V.
VC voltage of power source circuit input.
33
P27
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G8 line keys on key matrix is touched.
34
P26
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G7 line keys on key matrix is touched.
35
P25
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G6 line keys on key matrix is touched.
36
P24
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G5 line keys on key matrix is touched.
37
P23
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G4 line keys on key matrix is touched.
38
P22
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G3 line keys on key matrix is touched.
39
P21
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G2 line keys on key matrix is touched.
40
P20
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43-P46 terminal while one
of G1 line keys on key matrix is touched.
41
P17
OUT
Hood lamp driving signal.
To turn on and off relay(RY6). “L” level: During
Hood lamp ON. “H” level: During Hood lamp OFF.
42
P16
OUT
Hood lamp driving signal.
To turn on and off relay(RY5). “L” level: During
Hood lamp ON. “H” level: During Hood lamp OFF.
43
P15
OUT
Hood motor high / low driving signal.
To turn on and off relay(RY3). “L” level: During Hood
motor high. “H” level: During Hood motor low.
44
P14
OUT
Hood motor driving signal.
To turn on and off relay(RY4). “L” level: During
Hood motor ON. “H” level: During Hood motor OFF.
45-47
P13-P11
OUT
Terminal not used.
Pin No.
Signal
I/O
Description