The set value of the following simulation must be set to the default.
SIM No
ITEM
Normal setting (Default)
Phenomenon when the set value is
changed
NOTE
AR-C150
AR-C250
AR-C160/C270
46-1
A
50
50
50
The density and color balance in the low
density section of color copy are
changed.
Set to the default when
adjusting the copy quality.
Do not adjust the density in the
low density section by using this
simulation.
B
50
50
50
C
50
50
50
D
50
50
50
E
50
50
50
F
50
50
G
46
46
H
46
46
I
46
46
46-2
A – O
50
50
50
The density in the low density section of
monochrome copy is changed.
46-10 –
19
A – O
500
500
500
The color copy density and color
balance are changed. (each copy mode)
Set to the default when
adjusting the copy quality.
46-20
A – O
500
500
500
The color copy density and color
balance of all copy modes are changed.
Set to the default when
adjusting the copy quality.
All the functions of SIM 44-1 must be set to ENABLE.
SIM No
ITEM
NORMAL
SETTING
CONDITION
Phenomenon when set to DISABLE
NOTE
44-1
DEVE
ENABLE
Toner concentration correction for developer
use frequency is not performed.
Improper copy, toner dispersion, image high
density section abnormality, developer
dispersion, insufficient image density
All functions
must be set to
ENABLE.
HUMID
ENABLE
Process section corrections for change in
humidity (toner concentration, transfer
voltage, resist roller rotation speed
correction) are not performed.
Improper color balance, abnormality,
improper copy, toner dispersion, developer
dispersion, improper image density, image
shift, image flow, image dirt
DM POSI ENABLE
OPC drum phase correction is not performed. Image color shift, banding
HT
ENABLE
Half-tone image density correction is not
performed.
Improper half-tone image density, improper
copy, improper color balance, tone jump
TC
ENABLE
Transfer voltage correction for a change in
humidity or paper kind is not performed.
Half-tone image section abnormality,
improper image density, low density inside
image outline
MD
ENABLE
Correction (laser power) for use frequency of
OPC drum (change in sensitivity) is not
performed.
Insufficient image density
(The following adjustment items affect copy quality, but there is no need to adjust them frequently. In case of a trouble,
however, they should be checked and adjusted.)
1) Adjustment item: ADJ M1, ADJ M2, ADJ M4, ADJ M6
ADJUSTMENT ITEM
SIMULATION
ADJ M1
DV doctor gap adjustment
ADJ M2
DV roller main pole position adjustment
ADJ M4
High voltage adjustment
ADJ 1
Main charger grid voltage adjustment
8-2
ADJ 2
DV bias voltage adjustment
8-1
ADJ 3
Transfer voltage adjustment
8-6 (Old)
44-30 (New)
ADJ M6
Image density sensor adjustment
ADJ 1
Image density sensor calibration
44-13
ADJ 2
Image density sensor sensing position adjustment
44-23
(The following adjustment items do not affect copy quality directly.)
1) Adjustment items: ADJ M5, ADJ M11, ADJ M12, ADJ M14, ADJ M15, ADJ M16, ADJ M18, ADJ M19, ADJ M20, ADJ M23, ADJ M24, ADJ M25
(Relationship between servicing contents and copy quality adjustment)
Note that the procedures before and after the copy quality adjustment differ depending on the conditions of the machine and the servicing contents.
Follow the copy quality adjustment procedure flow to perform procedures according to the conditions.
There are following 5 major cases.
1) When installing
2) When performing the periodic maintenance
3) When replacing consumable parts in repair work
4) When not replacing consumable parts in repair/check work
5) When perform in repair/check work
7 – 25
Summary of Contents for AR-C150
Page 35: ... 5 EXTERNAL VIEW AND INTERNAL STRUCTURE ...
Page 135: ... 10 SELF DIAG MESSAGE AND TROUBLESHOOTING ...
Page 202: ... 14 OTHERS ...