(3) Items to be performed after maintenance servicing 3
Item
Simulation
Paper jam, trouble data clear
24
1
Each paper feed section use number counter clear
24
2
RADF, sorter, scanner use number counter clear
24
3
Maintenance counter clear
24
4
Setup and adjustment data output
22
6
(4) Maintenance display
When the maintenance timing is reached, the following display is shown.
MAINTENANCE REQUIRED CODE: XX
The above two-digit code indicates the kind and the count of the maintenance counter.
The meaning of the CODE indication is as shown below.
CODE (XX) 1st digit
Meaning
A
5K
Maintenance counter value set with SIM 21-1.
B
10K
C
15K
D
20K
E
40K
F
80K
CODE (XX) 2nd digit
Meaning
T
The total maintenance counter has reached the value set with SIM 21-1.
C
The color maintenance counter has reached the value set with SIM 21-1.
A
Both the total maintenance counter and the color maintenance counter have reached the values set with SIM 21-1.
After completion of maintenance, reset this display with SIM 24-4.