LC-60LE635E/636E/638E (1st Edition)
6 – 8
Table 1. Concrete flashing pattern
*2: It depends on the system. The power supply error suitable for the product is defined.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing disabled).
MONITOR ERR STBY table
Item
Expression for a rough content
Expression for Details
Cause
low-speed
blinking
high-speed
blinking
low-speed
blinking
high-speed
blinking
Lamp system failure Flashes once
—
Flashes once
Flashes once
Lamp error
Power PWB failure
Flashes twice
—
Flashes twice
Flashes once
Power Error 1 AC_DET error (*2)
(Power failure, etc.)
Flashes twice
Power Error 2 UR+13.5V error (*2)
Flashes 3 times
Power Error 3 D3.3V error (*2)
Flashes 5 times
Panel power supply error
Main PWB failure
Flashes 3 times
—
Flashes 3 times
Flashes once
Initial communication error
(Communication Flashes
twice
Start-up confirmation communication error
failure, etc.)
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Others
Flashes 4 times
—
Flashes 4 times
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main microprocessor
(*3)
Upgrade executing
smoothness
changes.
—
—
—
Version upgrading
Upgrade completion
a staircase
pattern.
—
—
—
Version upgrade succeeded
Upgrade failed
—
Flashing
(Continuous)
—
—
Version upgrade failed
ROM data failure
—
Flashing
(Continuous)
—
—
Start-up after failing version upgrade (*4)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2001) is stored on EEPROM, states can be confirmed in the
adjustment process mode.
Location: Page (1/20) of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the page (2/20) of the
adjustment process mode.
Display Error
description
02
Start-up communication error 2
Initial communication from the main CPU is not received.
03
Start-up communication error 3
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A
REQ time-out
0B
Communication error B
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C
Ending sequence time-out
0D
Communication error D
Preset start-up time-out during completion
0E
Communication error E
Download start-up time-out
0F
Communication error F
Time acquisition time-out
11
Communication error H
Regular communication time-out
16
Panel-related error
Lamp failure
1A
Other error 2
Monitor temperature failure
1D
Power supply error 1
PS_ON (AC_DET) failure
1E
Power supply error 2
D_POW (DET_13V) failure
1F
Power supply error 3
D_POW (DET_D3V3) failure
21
Power supply error 5
Panel power failure
23
Other error 3
Error standby request from the main CPU