LC-60/70EQ30U
6 – 2
[3] TROUBLESHOOTING TABLE
•
LED Backlight does not turn on.
If it is not an error of power supply/LED driver,
It is start-up in the lamp error disregard mode.
Do you start?
YES
When main unit is replaced, does it start normally?
YES
NO
Replace main unit.
When LCD control unit is replaced, does it start normally?
YES
NO
Replace LCD control unit.
When the parts in the panel can be replaced.
→
Replace all LED-bars in the panel module.
When the parts in the panel cannot be replaced.
→
Replace panel module.
If it is not an error of power supply/LED driver,
It is start-up in the lamp error disregard mode.
Do you start?
NO
When power supply unit is replaced, does it start normally?
YES
NO
Replace power supply unit.
When main unit is replaced, does it start normally?
YES
NO
Replace main unit.
When LCD control unit is replaced, does it start normally?
YES
NO
Replace LCD control unit.
When the parts in the panel can be replaced.
→
Replace all LED-bars in the panel module.
When the parts in the panel cannot be replaced.
→
Replace panel module.
Summary of Contents for AQUOS LC-60EQ30U
Page 7: ...LC 60 70EQ30U 2 1 LC 60EQ30U Service Manual CHAPTER 2 OPERATION MANUAL 1 OPERATION MANUAL ...
Page 8: ...LC 60 70EQ30U 2 2 㪣㪚㪄㪍㪇㪜㪨㪊㪇㪬 ...
Page 9: ...LC 60 70EQ30U 2 3 ...
Page 10: ...LC 60 70EQ30U 2 4 ...
Page 11: ...LC 60 70EQ30U 3 1 LC 60EQ30U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS LC 60EQ30U ...
Page 73: ...LC 60 70EQ30U ...