LC-60/70EQ30U
5 – 4
5. List of adjustment process mode menu
The character string in brackets [ ] will appear as a page title in the adjustment process menu header.
Page
Line
Item
Description
Remarks(adjustment detail,etc.)
1
1
Main Version
Main Software Version
2
SVN Number
Software version number of IC supplier
3
PANEL Version
LCD controller software version
4
TEMP SENSOR
Panel temperrature
5
NORMAL STANDBY CAUSE
6
ERROR STANDBY CAUSE
(*)
2
1
Factory Init
Initialization to factory settings
2
Inch Setting
3
Public Mode
4
Operation Acutime
Acumurate Time of TV-SET Operation.
5
RESET
Reset the Acumurate Time of TV-SET Operation.
6
MODEL SETTING
5
1
COMP HD ADJ
Auto adjustment of Component A/D for HD signal.
2
Y OFFSET
3
Pb OFFSET
4
Pr OFFSET
5
Y GAIN
6
Pb GAIN
7
Pr GAIN
8
RESET ADJUSTMENT
6
1
RGB ADJ
Auto adjustment of RGB A/D for PC signal.
2
G OFFSET
3
B OFFSET
4
R OFFSET
5
G GAIN
6
B GAIN
7
R GAIN
8
RESET ADJUSTMENT
8
1
IN POINT LOW
Standard value Low
In AV MODE : STAN-
DARD,MOVIE,GAME,USER,PC
2
IN POINT HIGH
Standard value High
3
IN POINT MAX
Standard value MAX
4
R LEVEL LOW
WB adjustment Point Low ,R adjustment value
5
G LEVEL LOW
WB adjustment Point Low ,G adjustment value
6
B LEVEL LOW
WB adjustment Point Low ,B adjustment value
7
Y LEVEL LOW
WB adjustment Point Low ,Y adjustment value
8
R LEVEL HIGH
WB adjustment Point High ,R adjustment value
9
G LEVEL HIGH
WB adjustment Point High ,G adjustment value
10
B LEVEL HIGH
WB adjustment Point High ,B adjustment value
11
Y LEVEL HIGH
WB adjustment Point High ,Y adjustment value
12
R LEVEL MAX
WB adjustment Point Max ,R adjustment value
13
G LEVEL MAX
WB adjustment Point Max ,G adjustment value
14
B LEVEL MAX
WB adjustment Point Max ,B adjustment value
15
Y LEVEL MAX
WB adjustment Point Max ,Y adjustment value
16
ADJ DATA STORE
17
RESET ADJUSTMENT
9
1
EEP CLEAR
Clear the EEPROM data
2
STANDBYCAUSE RESET
Clear the STANDBY CAUSE history.
3
DESTINATION
Indicate the kind of Factory-Initialization command
4
L ERR RESET
Indicate the count of Lamp Error Protection. And
Reset the counter
5
L ERR STOP
Lamp Error protection flag (Enable/Disable)
6
TEMP CAUTION
Setting for threshold level of High-Temp. caution
7
TEMP SHUTDOWN
Setting for threshold level of High-Temp. protection
8
1ST TEMP CONTROL (AD Value)
9
2ND TEMP CONTROL (AD Value)
10
TEST NETWORK UPDATE
10
1
VCOM ADJ
VCOM adjustment value
2
TCON TEST PATTERN
3
TEST PATTERN
4
Dimmer
5
FRC TEST PATTERN
Summary of Contents for AQUOS LC-60EQ30U