28
LC-37D40U
LC-45D40U
PC
Set
Adjust RB to the target xy values.
MG1RXXXX
MG1BXXXX
* XXXX indicates the adjusted values between 0000 and 1023
(4 digit decimal number with zero fill).
* G is fixed.
* The default adjustment value of RGB is the parameter value of
the LEV1 command multiplied by 2.
Adjustment values are set.
OK
Repeat until RGB
become the target
values.
The adjustment value is
reflected in the image.
Writing of adjusted values
MSET0003
Deletion is complete.
OK
Deleting adjustment patterns
MSET0000
Writing is complete.
OK
Start measurement
Completion of adjustment
2-7. Initialization to factory settings
After the shipping setting, pull off the AC cord.
Note: Never turn on the power after the shipping setting. If power is turned on, perform the shipping setting
again.
Adjustment item
Adjustment conditions
Adjustment procedure
1
Initialization
It turns off with AC pow-
er supply.
Place the cursor on the [INDUSTRY INIT] row, set "ON" with [+] or [-] of
the [VOL] key, and press the [ENT] key.
Version confirmation screen appears.
[SUCCESS] on a green line indicates that the setting is successfully
completed.
(In case of an error, [ERROR] and an error code appear on a red line.)
Turn off the AC power.
1. User setting
2. Channel data (e.g. broadcast frequencies)
3. Password data
4. Operation time
5. Auto installation flag
6. V-CHIP block setting
Summary of Contents for Aquos LC 45D40U
Page 45: ...45 LC 37D40U LC 45D40U M E M O ...
Page 53: ...6 5 4 3 2 1 A B C D E F G H 60 LC 37D40U LC 45D40U IF Unit Side A ...
Page 56: ...6 5 4 3 2 1 A B C D E F G H 63 LC 37D40U LC 45D40U AC INLET Unit LC 45D40U Only KEY Unit ...
Page 72: ...79 LC 37D40U LC 45D40U M E M O ...
Page 80: ...87 LC 37D40U LC 45D40U ...
Page 109: ...6 5 4 3 2 1 A B C D E F G H 142 LC 37D40U LC 45D40U LED Unit ...
Page 110: ...6 5 4 3 2 1 A B C D E F G H 143 LC 37D40U LC 45D40U KEY Unit ...