LC-37AD5E
3 – 20
[8] White Balance Adjustment
Adjustment gradation values (IN) appear on page 7/11 of process adjustment, and adjustment initial values (offset value) appear on pages 8/11 and
9/11. For white balance adjustment, adjust the offset values on pages 8/11 and 9/11.
[Condition of the unit for inspection] Modulated light: MAX (+8)
[Adjustment reference device] Minolta CA-210
[Adjustment]
Check that the values on page 7/11 of process adjustment are set as below. If not, change them accordingly.
1) Display the current adjustment status at point 6. (Page 8/11 of process adjustment)
The display for checking the adjustment status is toggled by pressing the “6” button on the remote control.
(Normal OSD display
→
“6”
→
display for check (OSD disappears)
→
“6”
→
normal OSD display
→
•
•
•
)
2) Read the value of the luminance meter.
3) Change M GAMMA R6/M GAMMA B6 (Adjustment offset value) on page 9/11 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
(Basically, G is not changed. If adjustment fails with R and B, change G. When G is lowered, the weaker of R and B must be fixed.)
4) If G is changed in step 3), change the values of M GAMMA G1-M GAMMA G5 on pages 8/11 and 9/11 of process adjustment as follows. When not
changed, go to step5).
Offset value of M GAMMA G1 = (Offset value of M GAMMA G6) * (160/960)
Offset value of M GAMMA G2 = (Offset value of M GAMMA G6) * (320/960)
Offset value of M GAMMA G3 = (Offset value of M GAMMA G6) * (480/960)
Offset value of M GAMMA G4 = (Offset value of M GAMMA G6) * (640/960)
Offset value of M GAMMA G5 = (Offset value of M GAMMA G6) * (800/960)
5) Display the adjustment status of the current point 5. (Each time the “5” button on the remote control is pressed, the adjustment status check dis-
play is toggled.)
(Normal OSD display
→
“5”
→
Check display (OSD disappears)
→
“5”
→
Normal OSD display
→
•
•
•
)
Change M GAMMA R5/M GAMMA B5 (adjustment offset value) on page 9/11 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
6) Repeat step 5) for points 4, 3, 2, and 1.
[Adjustment reference standard value]
M GAMMA IN 1
160
M GAMMA IN 2
320
M GAMMA IN 3
480
M GAMMA IN 4
640
M GAMMA IN 5
800
M GAMMA IN 6
960
Adjustment spec
±
0.004
Inspection spec
±
0.006 (point 1)
Adjustment spec
±
0.002
Inspection spec
±
0.004 (Excluding the above-mentioned)
Summary of Contents for AQUOS LC-37AD5E
Page 4: ...LC 37AD5E 1 1 LC37AD5E Service Manual CHAPTER 1 OPERATION MANUAL 1 SPECIFICATIONS urkish Gr ...
Page 5: ...LC 37AD5E 1 2 2 OPERATION MANUAL ...
Page 6: ...LC 37AD5E 1 3 ...
Page 7: ...LC 37AD5E 1 4 ...
Page 8: ...LC 37AD5E 1 5 ...
Page 9: ...LC 37AD5E 1 6 ...
Page 64: ...LC 37AD5E 5 5 2 3 IC301 IC302 VHiTDA8931T 1Y 2 3 1 Block Diagram ...
Page 79: ...LC 37AD5E 5 20 2 10 IC4203 RH iXC100WJZZQ 2 10 1 Block Diagram ...
Page 102: ...LC 37AD5E 8 3 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 2 11 13 12 14 15 16 18 19 17 ...
Page 103: ...LC 37AD5E 8 4 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 3 11 13 12 14 15 16 18 19 17 ...
Page 104: ...LC 37AD5E 8 5 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 5 11 13 12 14 15 16 18 19 17 ...
Page 105: ...LC 37AD5E 8 6 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 6 11 13 12 14 15 16 18 19 17 ...
Page 106: ...LC 37AD5E 8 7 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I AV Unit 11 13 12 14 15 16 18 19 17 ...
Page 109: ...LC 37AD5E 8 10 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I KEY Unit 11 13 12 14 15 16 18 19 17 ...
Page 140: ...LC 37AD5E 26 12 PACKING PARTS Not Replacement Item S2 S2 S2 S5 S4 S1 S2 S3 S5 S6 ...