LC-24LE150M
6 – 4
(19) Set the G of point Max. to the default value
(4080 x G value of point 2 / R2). Set the R,B
Max. value [G
max
– G value of point 2 + (R,B
value of point 2)
(20) Calculate the slope R2
slope,
G2
slope,
B2
slope
between MAX and Point2.
R2
slope =
(R
max
- R
high
)/(4080-
3664
)
(21) Calculate the correction value
پ
R
high,
پ
G
high,
پ
B
high.
R
high =
R2
slope X
(
3840-3664
)
(22)
Set the reference value R,G,B of point 2
(R2
’
)=R2+
پ
R
high
(23)
Calculate the slope R1
slope,
G1
slope,
B1
slope
between Point2 and Point1.
R1
slope =
(R
high
- R
low
)/(
3664
-816)
(24)
Calculate the correction value
پ
R
low,
پ
G
low,
پ
B
low.
R
low =
R1
slope X
(915-816)
(25)
Set the reference value R,G,B of point 1
(R1
’
)=R1+
پ
R
low
(26) Shut down the AC power.
䯲
Initial value at RGB 2 point :
3664
䯲
Initial value at RGB 1 point : 816
[Adjustment value]
侀
Teaching set send by engineering dept is set as
reference.
[Reference values for adjustment reference]
Equipment : Luminance meter [Minolta CA-210]
Level
Spec
Data
Adjustment
Spec.
Inspection
Spec.
Point
2 ref.
values
229
x=0.272
y=0.277
0.0010
0.0020
Point
1 ref.
values
51
x=0.272
y=0.277
0.0045
0.0090
Ref. : For inspection, set the LCD TV as below.
AV MODE
: [DYNAMIC] (Reset)
Aging Time
: Minimum 5 minutes
Summary of Contents for Aquos LC-24LE150M
Page 9: ...LC 24LE150M 4 1 CHAPTER 4 DIMENSIONS 1 DIMENSIONS mm ...
Page 26: ...LC 24LE150M 9 2 MAIN PWB SIDE A MAIN PWB SIDE A H F G E D C B A 2 10 9 8 7 6 5 4 3 1 ...
Page 27: ...LC 24LE150M 9 3 MAIN PWB SIDE B CHIP MAIN PWB SIDE H F G E F D C B A 2 10 9 8 7 6 5 4 3 1 ...
Page 28: ...LC 24LE150M 9 4 MAIN PWB SIDE B H F G E F D C B A 2 10 9 8 7 6 5 4 3 1 ...
Page 33: ...LC 24LE150M 9 9 POWER PWB SIDE B POWER PWB SIDE B H G E F D C B A 2 10 9 8 7 6 5 4 3 1 ...
Page 39: ...LC 24LE150M 10 6 4 POWER Unit A C B D E F G H 2 10 9 8 7 6 5 4 3 1 ...
Page 40: ...LC 24LE150M 10 7 19 18 17 16 15 14 13 12 11 10 ...
Page 53: ...LC 24LE150M 13 ...