CD-BA250/CD-BA2600
– 2 –
General
Amplifier
CD player
Tuner
Cassette deck
Power source
AC 120 V, 60 Hz
Power consumption
128 W
Dimensions
Width: 10-5/8" (270 mm)
Height: 13" (330 mm)
Depth: 13-7/16" (340 mm)
Weight
13.8 lbs. (6.3 kg)
Output power
75 watts minimum RMS per channel into 6 ohms from
60 Hz to 20 kHz, 10% total harmonic distortion
Output terminals
Speakers: 6 ohms
Headphones: 16 - 50 ohms (recommended: 32 ohms)
Input terminals
Video/Auxiliary (audio signal): 500 mV/47 kohms
Type
3-disc multi-play compact disc player
Signal readout
Non-contact, 3-beam semiconductor laser pickup
D/A converter
1-bit D/A converter
Frequency response
20 - 20,000 Hz
Dynamic range
90 dB (1 kHz)
Frequency range
FM: 87.5 - 108 MHz
AM: 530 - 1,720 kHz
Frequency response
50 - 14,000 Hz (Normal tape)
Signal/noise ratio
55 dB (TAPE 1, playback)
50 dB (TAPE 2, recording/playback)
Wow and flutter
0.3 % (WRMS)
Type
2-way type speaker system
2" (5 cm) Tweeter
5-1/4" (13 cm) Woofer
Maximum input power
150 W
Rated input power
75 W
Impedance
6 ohms
Dimensions
Width: 8-11/16" (220 mm)
Height: 13" (330 mm)
Depth: 8-9/16" (217 mm)
Weight
6.6 lbs. (3.0 kg)/each
FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER
TO THE OPERATION MANUAL.
Specifications for this model are subject to change without
prior notice.
SPECIFICATIONS
CD-BA250/CD-BA2600
CP-BA250/CP-BA2600
IMPORTANT SERVICE NOTES (FOR U.S.A. ONLY)
BEFORE RETURNING THE AUDIO PRODUCT
(Fire & Shock Hazard)
Before returning the audio product to the user, perform the
following safety checks.
1. Inspect all lead dress to make certain that leads are not
pinched or that hardware is not lodged between the chassis
and other metal parts in the audio product.
2. Inspect all protective devices such as insulating materials,
cabinet, terminal board, adjustment and compartment covers
or shields, mechanical insulators etc.
3. To be sure that no shock hazard exists, check for leakage
current in the following manner.
* Plug the AC line cord directly into a 120 volt AC outlet.
* Using two clip leads, connect a 1.5k ohm, 10 watt resistor
paralleled by a 0.15
µ
F capacitor in series with all exposed
metal cabinet parts and a known earth ground, such as
conduit or electrical ground connected to earth ground.
* Use a VTVM or VOM with 1000 ohm per volt, or higher,
sensitivity to measure the AC voltage drop across the
resistor (See diagram).
* Connect the resistor connection to all exposed metal parts
having a return path to the chassis (antenna, metal cabinet,
screw heads, knobs and control shafts, escutcheon, etc.)
and measure the AC voltage drop across the resistor.
All check must be repeated with the AC line cord plug connection
reversed.
Any reading of 0.3 volt RMS (this corresponds to 0.2 milliamp.
AC.) or more is excessive and indicates a potential shock
hazard which must be corrected before returning the audio
product to the owner.
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
TEST PROBE
0.15
µ
F
1.5k ohms
10W
VTVM
AC SCALE
Summary of Contents for AQUOS CD-BA250
Page 50: ...CD BA250 CD BA2600 50 MEMO ...