CHAPTER 2. ELECTRIC CIRCUIT
[1]
ELECTRIC PARTS
1. AH-129 / AU-129
DESCRIPTION
MODEL
REMARK
S
SIT
E
Compressor
RH207VXGT
220V, 50Hz, 1120W
OUTDOOR
Indoor fan motor
CMOT-A448JBKZ 220 - 240V , 50Hz
INDOOR
Outdoor fan motor
CMOTLB182JBEZ 220 - 240V , 50/60Hz
OUTDOOR
Indoor fan motor capacitor
—
450V, 2
µ
F
INDOOR
Outdoor fan motor capacitor
—
400V, 2
µ
F
OUTDOOR
Running capacitor
—
400V, 30
µ
F
OUTDOOR
Transformer
—
Primary ; AC 220 / 240V 50Hz
Secondary ; AC15.3V , 50Hz
INDOOR
—
Fuse
—
250V, 2.5A
INDOOR
2. AH-MP14 / AU-MP14
6
DESCRIPTION
MODEL
REMARK
S
SIT
E
Compressor
RH207VXGT
220V, 50Hz, 1120W
OUTDOOR
Indoor fan motor
CMOT-A448JBKZ 220 - 240V , 50Hz
INDOOR
Outdoor fan motor
CMOTLB182JBEZ 220 - 240V , 50/60Hz
OUTDOOR
Indoor fan motor capacitor
—
450V, 2
µ
F
INDOOR
Outdoor fan motor capacitor
—
400V, 2
µ
F
OUTDOOR
Running capacitor
—
400V, 30
µ
F
OUTDOOR
Transformer
—
Primary ; AC 220 / 240V 50Hz
Secondary ; AC15.3V , 50Hz
INDOOR
—
Fuse
—
250V, 2.5A
INDOOR
Summary of Contents for AH-129
Page 7: ... 2 MICRO COMPUTER CONTROL SYSTEM 1 Electronic Control Diagram Indoor unit AH 129 AH MP14 7 ...
Page 8: ...2 PRINTED WIRING DIAGRAM 2 1 Indoor AH 129 8 ...
Page 9: ...2 2 Indoor AH MP14 9 ...
Page 14: ...CHAPTER 4 TROUBLESHOOTING 14 ...
Page 15: ...CHAPTER 4 TROUBLESHOOTING 15 ...
Page 16: ...16 ...