AEXM24HR
1 – 1
AEXM24HR
Service Manual
CHAPTER 1.
SPECIFICATION
[1] SPECIFICATION
NOTE: The condition of star "
✩
" marked item are ‘ISO5151’: *
:
Representative connection
MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AY-XPM7FR/9FR/
X12FR
AE-XM24HR
Cooling capacity
kW
4-INDOOR OPERTION
7K&7K&7K&7K
7.0(3.0–8.2)*
Heating capacity
kW
4-INDOOR OPERTION
7K&7K&7K&7K
8.0(3.0–9.2)*
Moisture removal (at cooling)
✩
Liters/h
1.0X2&0.8*
Electrical data
Phase Single
Rated frequency
Hz
50
Rated voltage
V
230V
Rated current
Cool
A
10.0(2.7– 13.6)*
Heat
A
9.2(2.6 – 11.7)*
Rated input
✩
(Min. - Max.)
Cool W
2180
(600–
2980)*
Heat
W
2000 (560 – 2560)*
Power factor
✩
Cool %
95
Heat %
95
Compressor
Type
Hermetically sealed DC twin rotary
Model DA150A1F-20F
Oil charge
Ester oil VG74
Refrigerant system
Evaporator
Slit Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control Expansion
valve
Name of refrirerant
R410A
Refrigerant volume
2300g
Noise level (at cooling)
dB(A)
Hi/Low/Soft
High/Med/Low
7FR:37/34/28
49
9FR:39/36/28
12FR:40/37/29
Fan system
Drive
Direct drive
Air flow quantity
( at cooling)
.
m
3
/min.
Hight/Med/Low
7FR :8.0/7.4/5.4
43
9FR :8.6/7.9/5.6
12FR :9.8/8.5/6.9
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8”,1/4”
Maximum length (per unit)
m
20
Maximum length(total)
m
50
Maximum chargeless length
m
40
Maximum height difference
m
10
Drain joint
mm
O.D
φ
18
Others
Safety device
Compressor: Thermistor
Fan motors: Thermal fuse(indoor unit).
Thermal protecor(Out door unit)
Fuse, Micro computer control
Anti-mold polypropyene net of injection type
(Wasshable)
Net dimensions
Width
mm
790
940
Heigh
mm
278
800
Depth
mm
198
357
Net weight
kg
10
64
Summary of Contents for AE-XM24HR
Page 5: ...AEXM24HR 1 4 5 WIRING DIAGRAMS 1 FOR MODEL AEXM24HR CC373 ...
Page 39: ...AEXM24HR 5 5 ...