2
AY-X36RU
AE-X36RU
PRODUCT SPECIFICATION
[1] SPECIFICATION
MODEL
ITEMS
INDOOR UNIT
OUTDOOR UNIT
AY-X36RU
AE-X36RU
Rated cooling capacity (Min. - Max.)
Btu/h
33600 ( 7400
-
36000 )
Rated heating capacity (Min. - Max.)
Btu/h
34600 ( 15000
-
36000 )
Moisture removal (at cooling)
pints/h
7.4
Electrical data
Phase
Single
Rated frequency
Hz
60
Rated voltage
V
208/230
Rated current
Cool
A
17
(Min.-Max.)
Heat
A
16.5
Rated input
Cool
W
4100 ( 450
-
4300 )
(Min.-Max.)
Heat
W
3800 ( 560
-
4300 )
Compressor
Type
Rotary
Model
TNB306FPGMC
Refrigerant system
Evaporator
Aluminum Fin-copper tube type
Condenser
Aluminum Fin-copper tube type
Control
Expansion valve
Refrigerant
type
R410A
oz. ( g )
91.7 ( 2600 )
Noise level
(at cooling)
Turbo
dB(A)
54
65
High
50
Low
44
Soft
38
Noise level
(at heating)
Turbo
dB(A)
54
65
High
50
Low
44
Soft
38
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
Turbo
CFM(m3/min)
736 ( 20.8 )
2589(73.3)
High
647 ( 18.3 )
Low
530 ( 15 )
Soft
412 ( 11.7 )
Air flow quantity
(at heating)
Turbo
CFM(m3/min)
736 ( 20.8 )
2589(73.3)
High
647 ( 18.3 )
Low
530 ( 15 )
Soft
412 ( 11.7 )
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size (Gas line )
inch (mm)
5/8 (16)
Refrigerant tube size (Liquid line )
inch (mm)
1/4 ( 6.35 )
Maximum length
ft ( m )
98.4 ( 30 )
Maximum charge-less length
ft ( m )
24.6 ( 7.5 )
Maximum height difference
ft ( m )
32.8 ( 10 )
Additional charge
oz./ft ( g/m )
0.5 ( 50 )
Drain pipe O.D.
inch (mm)
5/8 (16 )
Others
Safety device
Compressor: Thermal protector
Pressure switch
Fuse, Micro computer control
Air fillters
Polypropylene net (Washable)
Net dimensions
Width
/
Height
/
Depth
inch
(mm)
53-1/7
/
12-5/6
/
10
( 1350
/
326
/
253 )
38-4/7
/
31-1/9
/
16-4/5
( 980
/
790
/
427 )
Net weight
lb. (kg)
41.9 ( 19 )
161 ( 73 )
NOTE: Test conditions are based on AHRI 210/240. ( Refrigerant piping length : 25ft [7.6m] )
* : Voltage is 230V